System Settings
Parameters
Setting values
STOPBIT
1 BIT*
2 BITS
HANDSHK .
SOFTWARE
HARDWARE
NONE*
DATABIT
7 BITS
8 BITS*
* Factory setting
Parameters in the "USB" Submenu
Parameters
Setting values
DEV .USED
NONE*
[Device Designation]
* Factory setting
7.3.3
Parameters in the "Data Output" Main Menu
Parameters in the "SBI Communication" Submenu
Parameters
Setting values
COM . OUTP .
IND .NO*
IND .AFTER
IND .AT
AUTO W/O
AUTO W/
STOP .AUTO
OFF*
ON
AUTO .CYCL .
EACH VAL*
2 . VALUE
FORMAT
16 CHARS
22 CHARS*
EXTR .LINE
AUTO .TARE
OFF*
ON
* Factory setting
34
Cubis
®
MCE Operating Instructions
Explanations
Sets the number of stop bits to 1 .
Sets the number of stop bits to 2 .
Sets the handshake protocol to software handshake .
Sets the handshake protocol to hardware handshake .
Does not set a handshake protocol .
Sets the number of data bits to 7 .
Sets the number of data bits to 8 .
Explanation
Indicates that no device connection is detected at the USB port .
Displays the designation of the devices connected to the USB port .
Explanations
Starts the data output after pressing the key or software command as an individual
value without stability .
Starts the data output after pressing the key or software command as an individual
value without stability .
Starts the data output after pressing the key or software command as an individual
value at stability .
Activates the automatic data output without stability .
Activates the automatic data output after stability .
Deactivates the option to abort the automatic data output .
The automatic data output is aborted by pressing the [PRINT] key or a software
command .
Starts the automatic data output with a cycle after each value .
Starts the automatic data output with a cycle after every 2nd value .
16 characters per line are data output .
Data output provides 22 characters per line (16 characters for the measured values
and 6 characters for identifiers) .
Data output provides an additional line with the date, time, and weight value .
Deactivates automatic taring after data output .
The device automatically tares after data output .