Related Tasks For Disk Drives Or Solid-State Drives; Preparing A Disk Drive Or Solid-State Drive For Use In An Aix System Or Logical Partition; Preparing To Remove A Disk Drive Or Solid-State Drive From A System Or An Expansion Unit Controlled By Aix; Rebuilding Data On A Replacement Disk Drive Or Solid-State Drive By Using Aix - IBM 8248-L4T Manual

Power systems. disk drives or solid-state drives
Hide thumbs Also See for 8248-L4T:
Table of Contents

Advertisement

Related tasks for disk drives or solid-state drives

Find additional information and instructions related to the disk drives or solid-state drives that help you
with performing the install, remove, or replace tasks.
Preparing a disk drive or solid-state drive for use in an AIX system or
logical partition
Configure the newly installed disk drive or solid-state drive for your environment.
If the drive is attached to a PCI-X SCSI RAID controller, see the PCI-X SCSI RAID Controller Reference
Guide for AIX in the IBM(r) AIX Information Center. If the drive is attached to another controller, see the
AIX System Management Guide: Operating System and Devices. These guides are available at the System p
and AIX Information Center (http://publib.boulder.ibm.com/infocenter/pseries/v5r3/index.jsp).
Preparing to remove a disk drive or solid-state drive from a system or
an expansion unit controlled by AIX
Learn the actions you must take to properly remove a disk drive or solid-state drive from a system or an
expansion unit controlled by AIX.
Before removing a drive from a system or expansion unit that is controlled by AIX, ensure that all data
on that drive or the array that contains the drive is backed up and removed from the drive. Also ensure
that the drive is in the Defined state.
If the drive is attached to a SAS RAID controller, see SAS RAID controllers for AIX. If the drive is
attached to a PCI-X SCSI RAID controller, see the PCI-X SCSI RAID Controller Reference Guide for AIX or
SAS RAID controllers for AIX topic. If the drive is attached to another controller, see the information for
that controller or the AIX System Management Guide: Operating System and Devices. These guides are
available at the System p and AIX Information Center.
Rebuilding data on a replacement disk drive or solid-state drive by
using AIX
To rebuild data on the replacement disk drive or solid-state drive, refer to the information for the
controller to which the drive is attached.
v If the disk drive or solid-state drive is attached to a PCI-X SCSI RAID controller, see the PCI-X SCSI
RAID Controller Reference Guide for AIX.
v If the disk drive is attached to a PCI SCSI RAID adapter (feature code 2498), see the PCI 4–Channel
Ultra3 SCSI RAID Adapter Reference Guide.
For more information, see the AIX System Management Guide: Operating System and Devices. These guides
are available at the System p and AIX Information Center.

Preparing to remove a disk drive or solid-state drive in a Linux system

Learn how to prepare the system to remove a disk drive or solid-state drive in a location that is
controlled by a system or logical partition that is running Linux.
© Copyright IBM Corp. 2013
®
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

8408-e8d9109-rmd

Table of Contents