• Place the module out of the box or after removal from the system with the component side to the top on a grounded and static-free surface. • Storage of an IMS module must be done in a dry place. • Installation or removal from hot-swap components only by authorized personnel! Date: 14th February 2020 IMS-MRI Setup Guide...
To ensure safe operation supply mains connected to this decice must be equipped with a fuse and a fault- current circuit breaker according to the applicable national standards for safe operation. The device must be connected to a protective earth with low grounding resistance according to the applicable national rules. IMS-MRI Setup Guide Date: 14th February 2020...
Wiring or any other work done the connectors particularly when connectors are opened may never be carried out when the installation is energized. All connectors must be covered to prevent from accidental contact to life parts. ALWAYS ENSURE A PROPER INSTALLATION! Date: 14th February 2020 IMS-MRI Setup Guide...
Make sure that the module is securely locked into the connector block before you fasten the two screws. Now you can put the installed module into operation. Attachment points of an 1U IMS system IMS-MRI Setup Guide Date: 14th February 2020...
"System". not "hot swappable" The central management unit must be disconnected from mains before replacement. RSC/SPT not "hot swappable" The RSC switching card must be disconnected from the mains before the replacement. Date: 14th February 2020 IMS-MRI Setup Guide...
10 MHz input, sine (1.5 V - 5 V or TTL, female BNC connector PPS input, TTL, pulse duration 5 s, active high, female BNC connector MRI - standard input signals Figure right: via BNC female connectors IMS-MRI Setup Guide Date: 14th February 2020...
Page 11
LED B: green, if 10 MHz or PPS or both signals are available at the same time Power Requirements: 5 V +-5%, 50 mA Date: 14th February 2020 IMS-MRI Setup Guide...
PPS). The provided input signals can be monitored and selected in the "Clock" menu after initializing. Menu MRS State: Displays the available input signals MRS settings: selection and prioritization of existing input sources IMS-MRI Setup Guide Date: 14th February 2020...