• Place the module out of the box or after removal from the system with the component side to the top on a grounded and static-free surface. • Storage of an IMS module must be done in a dry place. • Installation or removal from hot-swap components only by authorized personnel! Date: 1st July 2020 IMS-VSI Setup Guide...
To ensure safe operation supply mains connected to this decice must be equipped with a fuse and a fault- current circuit breaker according to the applicable national standards for safe operation. The device must be connected to a protective earth with low grounding resistance according to the applicable national rules. IMS-VSI Setup Guide Date: 1st July 2020...
Wiring or any other work done the connectors particularly when connectors are opened may never be carried out when the installation is energized. All connectors must be covered to prevent from accidental contact to life parts. ALWAYS ENSURE A PROPER INSTALLATION! Date: 1st July 2020 IMS-VSI Setup Guide...
Make sure that the module is securely locked into the connector block before you fasten the two screws. Now you can put the installed module into operation. Attachment points of an 1U IMS system IMS-VSI Setup Guide Date: 1st July 2020...
CPU is disconnected. Also the management and monitoring functions are no longer available. RSC/SPT: "hot swappable" The switching function or the distribution of generated signals is interrupted while the RSC/SPT is disconnected. Date: 1st July 2020 IMS-VSI Setup Guide...
LED B green, if Word Clk In and PPS are available flashing green, if only Word Clk In is available flashing yellow, if only PPS is available off, if no signal IMS-VSI Setup Guide Date: 1st July 2020...
Menü "IO Config Input Configuration VSI-Karte" Video Sync Interface: configurable Inputs Input 1: Video Sync In Format: PAL 625i Epoch: Signal Source: Single-ended signal input Time Code Modes: VITC Time Code Line: 6 - 22 Date: 1st July 2020 IMS-VSI Setup Guide...
Page 12
LTC In Type: LTC 25 FPS (Frames per Second) Daily Jam Time: Time of Day (hh:ii) Input 3: Word Clk In Port Type: GPIO (General Purpose Input Output) Direction: Input Operation Mode: Always enabled IMS-VSI Setup Guide Date: 1st July 2020...
Page 13
Input 4: PPS In Pulse length: 5 s, active high Date: 1st July 2020 IMS-VSI Setup Guide...
Need help?
Do you have a question about the IMS-VSI and is the answer not in the manual?