For this we recommend the use
of Bioguard Foam Descaler &
Sanitiser Spray.
13
Remember to include the drip
tray. If a Waste Overflow
System is fitted, empty this
and flush through with a small
amount of sanitisation fluid if
needed.
16
Fit new filter. Turn on incoming
water supply and reconnect the
power.
Borg & Overström
Pay particular attention to the
dispense faucet and the push
button controls. For this use
Bioguard External Sanitiser &
Clear Spray and Sanitising
Wipes.
14
When the external cleaning
(minimum 5 minutes) is completed,
flush the machine using the cold
button with clean water until the
dispense water runs clear. Repeat
briefly with the ambient and
sparkling buttons if present.
17
Pre-flush the new filter to waste
using the ambient button until
the water appears clear and is
free of air. Flush through a small
amount of water to check all
functions.
Please note that this sanitisation fluid contains an
active caustic/alkaline agent.
Always use responsibly and with care remembering
that due to its alkaline nature unnecessary
concentrated/prolonged contact with any materials,
including metals, can cause damage. Always rinse
all contact surfaces after use with clean water.
Install & Operation Manual
11
5
mins
PINK
19
12
5
mins
Attend to any cosmetic marks
with Bioguard Rejuvenator &
Protector as needed.
15
Turn off water and remove the
service filter. Retain service filter
for reuse.
Avoid skin contact and wear
protective gloves when
handling sanitisation fluids.