Sparkling Water Flow Rate - Sparkling Versions Only
NOTE: The soda water flow rate is set to 35ml/sec at a CO2 pressure of 58 PSI (4 bar). To
adjust the soda water flow rate follow these steps:
1
1
Remove the 3 screws holding
the unit lid down and lift the
lid away
Once the correct flow rate is achieved reverse steps 1, 2 and 3.
Borg & Overström
2
Locate the flow control adjuster,
this can be found on top of the
carbonator can, connected to
the central port of the can.
Install & Operation Manual
3
Loosen the lock nut, but do
not remove.
13
4
Flow can then be adjusted
by turning the adjuster screw,
anti-clockwise to increase flow
and clockwise to restrict flow.
After each adjustment the flow
rate should be timed.