Controls
Basic Settings
Adjusting the Set Point:
1. Switch on Mains power – the display will
flash several times, then the fridge system
will switch on and the display will give a
steady reading, this is the temperature of
the water bath sensor.
2. Press and release the 'Set' button – The
display will show 'SET'.
3. Press 'Set' again and the display will show
a numeric value (e.g. 9°C).
Altering the Differential setting:
1. Press and hold the 'Set' button until CP
shows on the display – Release the button.
2. Press 'Set again, DIF will show on the
display.
3. Press 'Set' again and the display will show
a numeric value, (e.g. 1°C, the default
setting.)
4. Raise or lower this figure to the desired
setting using the up or down arrows on the
left of the control display window.
NOTE: If no buttons are pressed for 15 seconds, the control will revert to temperature display
mode,and any changes to settings will be saved.
Install & Operation Manual
4. Raise or lower this figure to the desired
setting using the up or down arrows on the
left of the control display window.
5. When the correct setting is shown in the
display window press 'Set' button the
display will now show SET.
6. Press FNC button to return to the probe
temperature reading.
5. When the adjustment has been made press
'Set' again the display will show DIF.
6. If no further changes are required press
FNC again to exit.
16
Power Connection Socket
Note: the undercounter unit
automatically powers up when the
power lead is connected.