CLIK DELAY INSTRUCTIONS

Clik Delay Feature
This feature allows the user to delay programmed waterings for
a designated period (from 1-7 days) AFTER a Clik Event ends.
At the end of Programmed Clik Delay period, the controller will
resume normal automatic irrigation.
1. Turn the dial to the RUN Position
2. Press and hold the "+" button for 3 seconds, then turn the dial
to the OFF position
3. Release the "+" button. The display will show the program-
mable Clik Delay.
SENSOR DAYS LEFT
4. Press the "+" button to set Clik Delay duration (from 1 to 7 days).
5. Return the dial to the RUN position. Clik Delay is set.
After a Clik Event ends (rain sensor changes from wet to dry) the
Clik Delay feature will become active and the screen will display
Clik Delay duration. The day count down will occur 24 hours
after the start of Clik Delay.
SENSOR DAYS LEFT
An active Clik Delay can be cancelled by turning the dial to the
OFF position, waiting for OFF to stop flashing, then turning the
dial back to the RUN position.
Any station that is set to override sensor, as well as Lighting
Programs, will operate during a Clik Delay event.
Note: Use caution when using the
programmable Clik Delay feature with
Hunter Wind-Clik, Freeze-Clik, Soil- Clik,
and freeze component of Solar Sync and
Rain/Freeze Clik as the Clik Delay will
become active AFTER Clik Event from
these devices.