CONNECTING A HUNTER SOLAR SYNC
This controller is compatible with the Solar Sync and Wireless
Solar Sync systems. Solar Sync is a sensor system that will
automatically adjust the controller's watering schedule (based
on changes in local climate condition) by using the Seasonal
Adjust function. The Solar Sync uses a solar and temperature
sensor to determine evapotranspiration (ET), or the rate at
which plants and turf use water, and also includes Hunter
Rain-Clik and Freeze-Clik technology that will shut down
irrigation when it rains and/or during freezing conditions.
NOTE: Solar Sync will apply a default seasonal adjust
value of 100% until the first full day (24-hour period)
of weather measurements have been received from
the sensor.
NOTE: Enabling the Sensor Bypass switch has no
effect on the seasonal adjust updates from the
Solar Sync sensor. It will, however, bypass the Rain-
Clik and Freeze-Clik functionality of the sensor.
Installing Solar Sync Sensor
Connect the Green and Black wire
from the Solar Sync Sensor to the
"SEN" wiring terminals on the
controller. It does not matter which
wire connects to which terminal. Turn the dial to the "Solar
Sync Settings" position. The display will initially show dashed
lines and then will show the default Region setting (3) on the
left and the default Water Adjustment setting (5) on the right.
20
®
Adjust the Region as needed by using the
(refer to page 21 for explanation of Solar Sync Region setting).
Use the
button to advance to the right to adjust the Water
Adjust setting as needed (see page 22 for explanation of
Water Adjust setting).
Installing the Wireless Solar Sync
Connect the Green and Black wire from the Wireless Solar
Sync Receiver to the "SEN" wiring terminals on the controller.
It does not matter which wire connects to which terminal.
Turn the dial to the "Solar Sync Settings" position. The
display will initially show dashed lines and then will show the
default Region setting (3) on the left and the default Water
Adjustment setting (5) on the right. Adjust the region as
needed by using the
and
explanation of Solar Sync Region setting). Use the
to advance to the right to adjust the Water Adjust setting as
needed (see page 14 for explanation of Water Adjust setting).
Solar Sync Settings
Once the Solar Sync sensor is connected to the controller, two
numbers will appear in the display
when the dial is turned to the Solar
Sync Settings position. The number
on the left of the screen is the Region
setting, and the number on the right on the screen is the
Water Adjustment setting (as shown above).
ET SENSOR
and
buttons (refer to page 13 for
button
buttons