A<-B: The alarm will be triggered when the intruder crosses over the alarm line from B to A.
Click the "Draw" button and then drag the mouse to draw a line in the image. Click the "Stop" button to stop drawing. Click the "Clear" button to delete
the lines. Click the "Save" button to save the settings.
5.
Set the schedule of the line crossing alarm. The setup steps of the schedule are the same as the motion detection schedule setup.
※ ※ ※ ※
Configuration requirements of camera and surrounding area
1.
Auto-focusing function should not be enabled for line crossing detection.
2.
Avoid scenes with many trees or the scenes with various light changes. The ambient brightness of the scene should not be too low.
3.
Cameras should be mounted at a height of 10 ft or above.
4.
Keep the mounting angle of the camera at about 45°.
5.
The detected objects should not be less than 1% of the entire image and the largest sizes of the detected objects should not be more than 1/8
of the entire image.
6.
Make sure the camera can view objects for at least 2 seconds in the detected area for accurate detection.
7.
Adequate light and clear scenery are crucial for line crossing detection.

4.5.4 Intrusion

Intrusion: Alarms will be triggered if someone or something intrudes into the defined areas.
Go to the Analytics Intrusion interface shown below.
1.
Enable the region intrusion detection alarm and set the alarm holding time.
2.
Set alarm trigger options. The setup steps are the same as motion detection.
3.
Click the "Save" button to save the settings.
4.
Set the alarm area of the intrusion detection. Click the "Area" tab to go to the interface shown below.
Set the alarm area number on the right side. Up to 4 areas can be added.
Click "Draw Area" button and then click around the area where you want to set as the alarm area in the image on the left side (the alarm area
should be a closed area). Click "Stop Draw" button to stop drawing. Click "Clear" button to delete the alarm area. Click "Save" button to save
the settings.
5.
Set the schedule of the intrusion detection. The setup steps of the schedule are the same as motion detection schedule setup.
※ ※ ※ ※
Configuration requirements of camera and surrounding area
1.
Auto-focusing function should not be enabled for intrusion detection.