Gas supply connection

This appliance is factory set for use with
Natural Gas at 4" of water column pressure.
It can also be used on LP Gas at 11" of
water column pressure after conversion (see
'Converting to a different gas type').
A manual shut-off valve must be installed
in an accessible location in the gas line
external to the appliance for the purpose
of turning on or shutting off gas to the
appliance. (In Massachusetts such shutoff
devices should be approved by the Board of
State Examiners of Plumbers & Gas Fitters).
6
Gas connection to the product must use
the elbow supplied with a
thread.
Ensure the blue washer (supplied) is
located between the elbow and the
product inlet. Failure to use this will
cause a gas leak.
Blue washer
1
/
Elbow
" NPT external
2