Connect To Gas Supply - Fisher & Paykel CG905D Installation Manual

Gas stainless cooktop
Hide thumbs Also See for CG905D:
Table of Contents

Advertisement

FIT CLAMPING BRACKETS BASED ON THE
10
BENCHTOP THICKNESS
x 4
view from below
16-20mm
20-30mm
12

CONNECT TO GAS SUPPLY

LPG
Make sure the supply pressure
is regulated to 2.90 kPa, with
all the burners operating at
highest setting.
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut off by the customer, make sure the connection
is fitted with an isolating valve close to the cooktop.
If connecting the gas with a flexible hose:
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be certified, with an Rp ½" (ISO 7‐1) female thread connection.
The hose assembly must be as short as practicable and comply with relevant local code and regulation requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, flue, or chassis of underbench oven etc.)
30-40mm
40mm+
TG
Adjust to obtain a test point pressure of
1.5 kPa (Hong Kong) or 0.8 kPa (Singapore)
with all the burners operating at the
Arrow
highest setting.
11
SECURE TO BENCHTOP
13
CHECK ALL CONNECTIONS FOR GAS LEAKS
GAS
GAS
ON
ON
x 4
Repeat on all the other sides
Please check for leaks with soap solution
9