Starting-up and Operating the Wine Guardian

Control Settings

Controller Functions

ON/OFF – The ON/OFF button will be used to turn the system on or off. When set to the off
mode the control will not allow any of the outputs to energize effectively locking the system
out. It will not allow any outputs to energize until the system is turned on with the ON/OFF
button. It should be noted that high voltage will still be present at the main control board when
the system is set to off even though the control will not allow it to switch to the outputs.
UP Arrow – The UP arrow will allow the user to increase settings.
DOWN Arrow – The DOWN arrow will allow the user to decrease settings.
SETTINGS – The setting button will be used to select between HEAT, COOL and AUTO
MODE, as well as entering the configuration settings. Holding the SETTINGS button for 5
seconds will enter configuration mode. Once in configuration mode the user can adjust settings
by pressing the UP or DOWN arrows. Pressing the SETTINGS button once will advance to the
next configuration settings. Holding the SETTINGS button for 5 seconds while in configuration
mode will store all changes and exit configuration mode.
For cooling operation only: Cooling for 60Hz models is set at 55°F from the factory and 13°C
for 50Hz models. This can be changed by hitting the UP or DOWN arrow, but please refer to
configuration settings # 2 and # 3 for limitations in comparison to the High and Low
temperature alarm settings.
For units with optional humidifier controlled by TTW WG: The RH% is factory set at
55%. This can be changed by referring to configurations setting # 6. If no humidifier is
attached, the control will read RH%, but will not be controlling it.
Changing fan operation: The default setting from the factory is "AUTO" fan. If desired it can
be changed to fan "ON" by accessing configuration setting #
42
The control has been wired and set up in the factory for
testing with default settings. It is an electronic digital
thermostat for one-stage cooling. No additional
adjustments should be necessary except adjusting the
cellar temperature to your preference. If additional
adjustments or changes are necessary, please refer to the
configuration settings section in this manual.