Advanced Settings
Advanced Settings-
Compressor anti-
short cycling time
Set up remote
sensor
or thermostat
Enable or disable
defrost sensor
input
38
Setting 8
Press "Settings" button to advance to Setting 8.
Press the "Up" or "Down" arrow buttons to
adjust number to the access code 12. Press
"Settings" button to continue onto setting 9
through 19.
Setting 9
Press the "Up" or "Down" arrow buttons to
adjust to the desired time in one minute
increments. Maximum is 10 minutes, minimum
is 0 minutes.
Compressor anti-short cycling time is the amount
of allowable time between compressor stop and
restart. Rapid start/stop of compressors can cause
premature failure. Factory default is 5 minutes.
WINE GUARDIAN DOES NOT
RECOMMEND SETTINGS LOWER THAN
FACTORY DEFAULT.
Setting 10
Press "Settings" button to advance to Setting
10.
Press the "Up" or "Down" arrow buttons to
adjust to the desired setting.
Remote sensor
Remote interface
Local interface – Through-the-wall
unit only (can also be installed as
option for TTW)
Averaging – Jumper position within
sensors must be adjusted. See page 30.
Setting 11
Press "Settings" button to advance to Setting
11.
 Press the "Up" or "Down" arrow buttons
to adjust to the desired setpoint
 1 will equal enabled and a 0 (zero) will
equal disabled.