Installation - preparation

Unpacking the hob:
Take care not to drop any parts.
Fitting position of the hob:
This appliance must be, when
installed, a minimum of 50mm
from any back wall and a minimum
of 55mm away from any adjacent
vertical surfaces, e.g. a tall cupboard
end panel. The 55 may be reduced
to 50mm if the adjacent surface
is resistant to fire (tiles or steel for
example). These dimensions are
shown in Fig.8 on page 30.

Ventilation requirements:

This appliance must be installed to
allow air to flow freely to the air intake
and from the air outlet. An air gap of
25mm is recommended immediately
below the hob (minimum of 10 with
oven below).
Failure to allow sufficient ventilation
could cause problems with operation
or damage to the hob and constitutes
incorrect installation, which is not
covered by the product's warranty
(Figs. 4 and 5).
Installation above a cupboard unit
25mm
30mm
5 10mm
Fig.4
Installation above an oven unit
Minimum
10mm
500 x 20mm
Fig.5
500x10mm
÷
500 x 10mm
5 10mm
÷
27