TECHNICAL INFORMATION FOR THE INSTALLER

In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown in fig.
15a has to be made, bearing in mind the following:
A 40mm ventilation gap must be provided between the bottom of the appliance and
any cabinetry, draw unit, thermal protection barrier or appliance.
If the cooktop is installed directly above an oven (which does not have a cooling fan
motor) or if its base is accessible through a cupboard or drawer space after installation, a
thermal protection barrier must be installed below the base of the cooktop as indicated
in fig. 1c.
If the oven installed below the cooktop has a cooling fan motor, the thermal protection
barrier is not required.
If the cooktop is installed above an oven, the two appliances shall be connected to the
gas and/or electrical supply with independent connections.
The cooker top must be kept no less than 200 mm away from any side wall (from side
edge of cutout - figs. 1a, 1b).
The hob must be installed at least 60 mm from the wall (from rear edge of cutout - fig.
1a).
There must be a distance of at least 650 mm between the hob and any wall cupboard or
extractor hood positioned immediately above (see fig. 1b).