TECHNICAL INFORMATION FOR THE INSTALLER
In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown in fig.
15a has to be made, bearing in mind the following:
•
A 40mm ventilation gap must be provided between the bottom of the appliance and
any cabinetry, draw unit, thermal protection barrier or appliance.
•
If the cooktop is installed directly above an oven (which does not have a cooling fan
motor) or if its base is accessible through a cupboard or drawer space after installation, a
thermal protection barrier must be installed below the base of the cooktop as indicated
in fig. 1c.
•
If the oven installed below the cooktop has a cooling fan motor, the thermal protection
barrier is not required.
•
If the cooktop is installed above an oven, the two appliances shall be connected to the
gas and/or electrical supply with independent connections.
•
The cooker top must be kept no less than 200 mm away from any side wall (from side
edge of cutout - figs. 1a, 1b).
•
The hob must be installed at least 60 mm from the wall (from rear edge of cutout - fig.
1a).
•
There must be a distance of at least 650 mm between the hob and any wall cupboard or
extractor hood positioned immediately above (see fig. 1b).