TECHNICAL INFORMATION FOR THE INSTALLER

In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown in fig.
1.1a has to be made, bearing in mind the following:
A 30mm ventilation gap must be provided between the bottom of the appliance and any
cabinetry, draw unit or appliance.
If the base of the cooktop is accessible through a cupboard or drawer space after installation,
a thermal protection barrier is not required.
If the cooktop is installed above an oven, the two appliances shall be connected to the gas
and/or electrical supply with independent connections.
The cooker top must be kept no less than 100 mm away from any side wall (from side edge
of cutout - figs. 1, 2).
The hob must be installed at least 50 mm from the wall (from rear edge of cutout - fig. 1).
There must be a distance of at least 650 mm between the hob and any wall cupboard or
extractor hood positioned immediately above (see fig. 2).