Disposal Of Ashes; Replacement Of Refractory Panels - Valcourt ANTOINETTE FP7CB Installation And Operation Manual

Hide thumbs Also See for ANTOINETTE FP7CB:
Table of Contents

Advertisement

7.5

Disposal of Ashes

Ashes should be placed in a metal container with a tight fitting lid. The closed container of
ashes should be placed on a non-combustible floor or on the ground, well away from
combustible materials pending final disposal. If the ashes are disposed of by burial in soil or
otherwise locally dispersed they should be retained in the closed container until all cinders have
thoroughly cooled.
7.6

Replacement of Refractory Panels

Do not use the fireplace with a broken or missing refractory panel.
Here are the steps to replace the refractory panels of your FP7 LM Antoinette fireplace. Note
that the steps are the same for the contemporary refractory panels.
1. Remove the Andirons (VA7070) by unscrewing the anchoring bolts. Figure 42.1
2. Remove the bottom refractory panel (22198). Figure 42.2
3. Unscrew the refractory panel retainers (2x: 1 left and 1 right) (PL64601). Figure 42.3
4. Remove the left and right side refractory panels (22195 and 22194) or (22332 and 22331)
Figure 42.4
5. Remove the back refractory panels (22196 and 22197) or (22333 and 22334). Figure 42.5
6. To reinstall the replacement refractory panels, just follow the steps in reverse.
WARNING: DO NOT USE MATERIALS OTHER THAN THOSE LISTED IN THE
REPLACEMENT PARTS SECTION DURING INSTALLATION AS
THEY MAY BE SAFETY HAZARDS AND A FIRE COULD RESULT.
Figure 41: Replacing Antoinette refractory panels
51