Page 1
FP1LM Manoir Qualified Clean Burning Decorative Fireplace Installation And Operation Manual U.S. EPA Low Mass Wood‐burning Safety tested according to ULC S610 and UL 127 Standards by Intertek Fireplace voluntary program phase 2 emission level qualified model www.valcourtinc.com Manufactured by: Stove Builder International Inc. 250 rue Copenhague, Saint‐Augustin‐de‐Desmaures (Quebec), Canada, G3A 2H3 Tel.: (418) 878‐3040 Fax: (418) 878‐3001 This manual is available for free download on the manufacturer’s web site. It is a copyrighted document. Re‐sale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual ...
Page 2
THANK YOU FOR CHOOSING THIS VALCOURT FIREPLACE As one of North America’s largest and most respected wood stove and fireplace manufacturers, VALCOURT takes pride in the quality and performance of all its products. We want to help you get maximum satisfaction as you use this product. In the pages that follow you will find general advice on wood heating, detailed instructions for safe and ...
PART A – INSTALLATION ............... 5 Safety Information ..........................5 1.1.1 Regulations Covering Fireplace Installation ..................7 General Information..........................7 1.2.1 FP1LM Manoir Wood Fireplace Specifications .................7 1.2.2 The Benefits of EPA Voluntary Emission Program «Low Mass» Phase II ........ 10 Fireplace Installation ......................... 10 1.3.1 Installation of a Gas Log Set ...................... 10 1.3.2 Locating the FP1LM Manoir Wood Fireplace ...
Page 4
Appendix 1: Optional Hot Air Distribution Kit Installation (AC01375, AC01376 or AC01340) ............. 51 Appendix 2 : Blower Maintenance or Replacement ......62 Appendix 3: Exploded Diagram and Parts List ........65 VALCOURT LIMITED LIFETIME WARRANTY ........68 REGISTER YOU WARRANTY ONLINE To receive full warranty coverage, you will need to show evidence of the date you purchased your unit. Keep your sales invoice. We also recommend that you register your warranty online at ...
PART A – INSTALLATION THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES). 1.1 Safety Information CAUTION: NEVER USE GASOLINE, GASOLINE‐TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR ‘‘FRESHEN UP’’ A FIRE IN THIS FIREPLACE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE FIREPLACE AT ALL TIMES. CAUTION: ...
Page 6
CAUTION: OPERATE ONLY WITH GLASS DOORS FULLY CLOSED OR FULLY OPEN WITH MECHE DOORS ALWAYS CLOSED. IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE. NEVER LEAVE THE FIREPLACE UNATTENDED WHEN IN USE. WARNING: THIS FIREPLACE HAS BEEN TESTED FOR USE WITH OPEN DOORS IN CONJUNCTION WITH MECHE DOORS ALWAYS CLOSED. THE MECHE DOORS MAY BE OPENNED ONLY DURING LIGHTING ...
1.1.1 Regulations Covering Fireplace Installation When installed and operated as described in these instructions, the FP1LM Manoir wood fireplace is suitable for use as a fireplace appliance in residential installations. In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code requirements. In the USA, the NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel‐Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code requirements. NOTE: The Fireplace is not approved for use with a so‐called “positive flue connection” to the clay tile of a masonry chimney. ...
1.2.2 The Benefits of EPA Voluntary Emission Program «Low Mass» Phase II In the past, most conventional masonry and low‐mass, factory‐built fireplaces were not efficient at producing usable heat. Typically, over 90 percent of the heat generated by a fireplace was lost out the chimney. In addition, many of these fireplaces were sources of smoke, indoors and out. In 2009, the US Environmental Protection Agency (EPA) initiated a voluntary program for manufacturers of decorative wood burning fireplaces to encourage manufacturers to produce clean wood‐burning appliances that reduce air pollution. Under the U.S. EPA Low Mass Fireplace Voluntary Program, cleaner burning fireplaces are ones that qualify for the Phase I emission levels of 7.3 g/kg (approximately 57 percent cleaner ...
1.3.2 Locating the FP1LM Manoir Wood Fireplace A. The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the outside air kit and chimney. If possible, you should choose a location where the chimney will pass through the house without cutting floor or roof rafters. Also choose a location that allows installing the least amount of offsets in the chimney. ...
Page 12
MINIMUM CLEARANCES MEASUREMENTS A 72" (1829 mm) minimum E 2" (51 mm) B 12" (305 mm) maximum 12 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 13
13 FP1LM Manoir ‐ Installation and Operation Manual...
Page 14
In the case where (F) would be equal to 4", it is suggested that the sheet metal between the base of the fireplace and floor be in one piece. In the case where the fireplace is installed directly on the floor the joint between the hearth extension and the fireplace (E) must also be protected by a non‐combustible material. For example, a sheet metal (not included). Note that the floor under of the fireplace should match or exceed the height of the floor protection. 14 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 15
MINIMUM MEASUREMENT E 2" (51 mm) A noncombustible floor protection must be installed in front of the unit. For more details see Section 1.3.3: Minimum Heart Extension Requirements. The use of an R value is convenient when more than one material is going to be used in the hearth extension to cover the combustible surface. This is because R values are additive, whereas K values are not. To find the corresponding R factor to use for some selected materials, please see Thermal Characteristics of Common Floor Protection Materials table. CAUTION: DO NOT LEAVE CARPET UNDER THE FLOOR PROTECTION IN FRONT OF THE FIREPLACE 15 FP1LM Manoir ‐ Installation and Operation Manual...
1.3.2.2 R‐Value Calculations There are two ways to calculate the R factor of the floor protection. First, by adding the R‐values of the proposed materials or if some K and thickness values are given, by converting them to R values. To calculate the R factor for a composite floor protection made of a combination of alternative materials, simply add the R‐values of those materials. If the result is equal to or larger than the required R value, the combination is acceptable. For R‐values of some selected materials, see Table Thermal Characteristics of Common Floor Protection Materials. Example: ...
1.3.4 Framing, Facing, Mantel, and Combustible Shelf 1.3.4.1 Framing The construction of the framing, facing, and mantel must be in accordance with the standards and the following illustrations: A. Frame the fireplace using 2" × 3" (5 cm x 8 cm) or heavier lumber. WARNING: COMBUSTIBLE FRAMING MATERIAL CANNOT BE USED IN THE SPACE DIRECTLY ABOVE THE FIREPLACE, EXCEPT FOR THE STUDS ABOVE THE FACING THAT SUPPORT THE FACING MATERIAL ...
Page 20
Wall finish behind the fireplace’s faceplate installation CLEARANCES MEASUREMENTS A 2" (51 mm) E* 41 1/8" (1045 mm) B* 6 7/8" (175 mm) F* 25 1/2" (648 mm) C* 72" (1829 mm) minimum G 1 3/8" (35 mm) MAX D* 5 1/2" (140 mm) *When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. 20 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 21
See Section 1.3.5: Fresh Air Intake Kit for fresh air kit (K) and Appendix 1: Optional Hot Air Distribution Kit Installation (AC01375, AC01376 or AC01340) for the different hot air distribution kits (L) installation. Fresh air intake kit or forced air kit installation LEGEND Combustible material allowed in this area Non‐combustible material only in this area MINIMUM MEASUREMENTS MINIMUM MEASUREMENTS FOR FRESH AIR INTAKE (K)** FOR FORCED AIR KIT (L)** H* 12" (305 mm) 18" (457 mm) J* 12" (305 mm) 18" (457 mm) *When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. ** The fresh air intake kit may be installed on the left side only and the forced air kit may be installed either on the sides or on the back. 21 FP1LM Manoir ‐ Installation and Operation Manual...
Page 22
CLEARANCES** M* 54 9/16" (1386 mm) N* 77 3/16" (1961 mm) *When drywall panels or any other finishing material inside the chase around the fireplace is to be used, add its thickness to the measurement. **Values M and N are minimum measurements. They may need to be increased to alloy installation of a Fresh air intake kit or forced air kit, or depending on the finish material used. CLEARANCES A 6" (152 mm) maximum B 18 1/2" (495 mm) minimum C 24" (610 mm) minimum *Measurements for (C) clearances are taken from door opening. 22 FP1LM Manoir ‐ Installation and Operation Manual ...
1.3.4.2 Facing Materials directly in the front of the fireplace, must be non‐combustible and have the minimum dimensions shown below. 2. Non‐combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace decorative frame. CAUTION: MATERIALS MUST BE INSTALLED SO THAT THE FACEPLATE MAY BE REMOVED AFTER THE INSTALLATION. ...
1.3.4.3 Compliance of a Combustible Mantel Shelf To ensure compliance of an existing mantel shelf or to install a combustible mantel shelf, refer to table and figure in this section. For example, a mantel shelf with a 6’’ depth (152 mm) ((C) value) must be installed at least 48" (1219 mm) ((B) value) above the bottom of the fireplace (see figure and tables in this section). Different mantel ...
1.3.5 Fresh Air Intake Kit During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust fans may compete for air, causing negative pressure in the house, resulting in smoke entering the house from the fireplace. This situation is aggravated in modern airtight houses. To overcome this problem, we strongly recommend that you bring fresh air to the fireplace. Check with local authorities having jurisdiction in your area, it may be mandatory. ...
Page 26
To complete the installation, make a hole of 1/4" to 1/2" (6 mm à 13 mm) bigger than the insulate pipe diameter in the outside wall of the house at the chosen location. From outside, place the outside air inlet cap in the hole (open side down) and fasten the register to the wall, with screws as shown bellow. Place the insulated pipe over the register tube and over the fireplace outside air connector. At each end, carefully pull back the insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe using pipe clamps. For a better seal, you may also use aluminum tape. Wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in place using aluminum tape. 26 FP1LM Manoir ‐ Installation and Operation Manual ...
1.3.6 Faceplate Installation VA1FE05 or VA1FE06 (Sold Separately) In order to perform installation of VA1FE05 or VA1FE06 faceplate, refer to Installation manual included in the faceplate kit. VA1FE05 VA1FE06 Façade moderne ‐ noir métallique Façade à bandes étroites ‐ noir métallique 27 FP1LM Manoir ‐ Installation and Operation Manual...
1.3.7 The Use of the Fire Screen To take advantage of mesh doors, the glass doors can be retracted toward the inside of fireplace. Note that the mesh door may be removed for cleaning purposes, but must always be in place and closed when the fireplace is in use, even if the glass doors are closed. OPERATE ONLY WITH GLASS DOORS FULLY CLOSED OR FULLY OPEN WITH MECHE DOORS ALWAYS CLOSED. IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE. NEVER LEAVE THE FIREPLACE UNATTENDED WHEN IN USE. ...
1.4 Venting System (Chimney and Chimney Connector) 1.4.1 General Information The venting system is the engine that drives your wood heating system. Even the best fireplace will not function safely and efficiently as intended if not connected to a suitable chimney. The heat in the flue gases that pass from the fireplace to the chimney is not wasted heat. This heat is what the chimney uses to make the draft that draws in combustion air and keeps the combustion gases within the fireplace. You can think of heat in the flue gas as the fuel the chimney uses to make draft. 1.4.2 Suitable Chimneys This wood fireplace may be connected to either a factory‐built metal or a masonry chimney. Whether metal or masonry, the chimney must have a number of characteristics to be suitable. To be suitable, a factory‐ built metal chimney must comply with UL 103HT (U.S.A.), ULC S629 (Canada), ULC S‐604 (Canada) or UL S‐ 610 (U.S.A). Factory‐built chimneys are tested as a system with all the necessary components for installation. The instructions provided with the chimney by its manufacturer are the only reliable source of ...
1.4.3 Chimney Installation Notes 1. If possible, install an interior chimney as it will provide better performance. In areas with continuous temperatures below 18 C (0 F), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start‐up characteristics. Exterior chimneys are also prone to down‐drafting and flow reversal. Installations, which are located on lower floors in the house, such as in a basement, in combination with outside chimney, are especially prone to flow reversal. 2.
Page 32
7. Deviations should be avoided whenever possible, especially the most pronounced. Each deviation adds some restriction to the chimney system and may lead to draft problems. 8. If the chimney extends higher than 5 ft. (1.5 m) above its point of contact with the roof, it must be secured using a roof brace. 9. A rain cap must be installed on top of the chimney. Failure to install a rain cap may cause corrosion problems. ...
1.5 Chimney Installation Instructions Always refer to the chimney manufacturer’s Installation manual to ensure a safe installation. Some non‐ illustrated parts may be required. 1.5.1 Examples of Typical Chimney Installation To insure a good draft, it is recommended to have a length of 18 A inches from the top of the unit to the first ...
Page 34
Direct installation Exterior offset installation 34 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 35
Interior offset installation Connection to a masonry chimney 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb bob to line up the center of the holes. Make sure that the size of the floor and ceiling holes are in accordance with the chimney manufacturer’s instructions. 2. From below, install a firestop (B) supplied by the chimney manufacturer in each ceiling/floor separation through which the chimney will pass. At the attic level, install a radiation shield from above (D). 3. Follow the chimney’s manufacturers’ instructions and place the first chimney length on the fireplace. For all chimneys, you must use an anchor plate (A) supplied by the chimney manufacturer before ...
Page 36
installing the first chimney length. Continue installing chimney lengths making sure to lock each length in place. 4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support (not illustrated). (Refer to instructions included with the support). 5. Then, put the roof flashing (E) in place and seal the joint between the roof and the flashing with roofing pitch. For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles. Nail the flashing to the roof, using roofing nails. 6. Place the storm collar (F) over the flashing, and tighten it with the bolt supplied. Finally, seal the joint between the storm collar and the chimney, using silicone caulking. 7. Install the chimney cap (G). 8. When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the ventilating openings. ...
Page 37
THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED NOTE: THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION. 37 FP1LM Manoir ‐ Installation and Operation Manual...
1.5.2 Offset Chimney Installation TABLE 2 – THE MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS Fireplace model FP1LM MANOIR WOOD FIREPLACE Chimney model All models listed in Table 1 Vertical installation 15 ft. (4.5 m) Two (2) elbows 15 ft. (4.5 m) Four (4) elbows 17 ft. (5.2 m) After reaching the location requiring the elbow, proceed as follows: 1. To insure a good draft, it is recommended, but non‐mandatory, to have a length of 18 inches (457 mm) from the top of the unit to the first offset. Install the first elbow; turn it in the required direction. Secure it to the chimney according to the chimney manufacturer’s instructions. In many cases, it is recommended to secure connections with three (3) ½" (12 mm) metal screws. 2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together according to the chimney manufacturer’s instructions. In many cases, it is recommended to use three (3) ½" (12 mm) metal screws. If the offset length is made of two (2) chimney lengths or more, many chimney ...
A INSULATED WALL RADIATION SHIELD B GYPSUM BOARD C INSULATED WALL 1.5.4 Chimney Support Installation 1.5.4.1 Universal Roof Support This support has three possible uses: 1. It must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset. 3. It may be used on a floor, ceiling or roof as a supplementary support. For roof support installation, refer to the instructions provided with the support by the chimney manufacturer. Many manufacturers will provide the maximum height of chimney that can be supported by the support. Make sure you respect those parameters. 39 FP1LM Manoir ‐ Installation and Operation Manual...
1.5.4.2 Universal Offset Support This support is used to support the chimney above an offset. When the chimney offset is used to pass through a wall, this support may be used on the wall to support the chimney. For offset support installation, refer to the instructions provided with the support by the chimney manufacturer. Many manufacturers will provide the maximum height of chimney that can be supported by the support. Make sure you respect ...
Page 41
Follow these steps: 1. Position the fireplace in its location. Temporarily install the elbow or chimney section (A) on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney. 2. In the middle of the oval, drill a hole in the masonry chimney at 45 or 30. 3. Increase the size of the hole until a 45 or 30 insulated liner adapter (B) can be easily slipped through. ...
PART B ‐ OPERATION AND MAINTENANCE 2.1 Fuel The FP1LM MANOIR is designed to work best when fuelled with seasoned cordwood. Use solid wood or processed solid fuel fire logs only. Hardwoods are preferred to softwoods since the energy content of wood is relative to its density. Hardwoods will result in a longer burning fire and less frequent refuelling. A moisture content of 15% to 20% (seasoned) is recommended. Wood that has been cut and split and let to ...
2.2 Operating the FP1LM Manoir Wood Fireplace CAUTION: WHEN USING THE DECORATIVE APPLIANCE, THE FIREPLACE DAMPER MUST BE SET IN THE FULLY OPEN POSITION. 2.2.1 First Fires Two things will happen as you burn your first few fires; the paint cures and the internal components of the fireplace are conditioned. As the paint cures, some of the chemicals vaporize. The vapors are not poisonous, but they do smell bad. Fresh paint fumes can also cause false alarms in smoke detectors. So, when you first light your fireplace, be prepared by opening doors and/or windows to ventilate the house. As you burn hotter and hotter fires, more of the painted surfaces reach the curing temperature of the paint. The smell of curing paint does not disappear until you have burned one or two very hot fires. Burn one or two small fires to begin the curing and conditioning process. Then build bigger and hotter fires until there is no longer any paint smell from the fireplace. Once the paint smell disappears, your fireplace is ready for serious heating. 2.2.2 Building a Fire To start a fire, place several crumpled up balls of newspaper in the firebox behind the andiron. Place small dry pieces of kindling on top of the paper, criss‐crossing the kindling so that there are air spaces in between. Open the exhaust damper fully and light the newspaper. Once the newspaper and the kindling are well ignited, you may close the glass door for a few minutes so that the firebox and chimney of your fireplace ...
2.2.4 Air Intake Control and Exhaust Damper The air intake control (dilution air) and exhaust damper should be in the closed position when there has not been any wood or embers in the fireplace for a few hours. This will minimize air leakage up the chimney. A OPEN position B CLOSE position Air Intake Control Exhaust Damper 2.2.5 Smoking Causes and Troubleshooting Your fireplace has been designed and tested to provide smoke free operation. Occasionally, there may be a small amount of smoking upon lighting the fire, until the chimney heats up but this should not continue. If the fireplace continues to smoke it is probably for one of the following reasons: A. Closed exhaust damper Make sure that the exhaust damper is in the open position (see Section 2.2.4: Air Intake Control and Exhaust Damper). B.
C. Wet wood Wet or tarred wood will smoulder and smoke instead of burning properly. D. Dirty or blocked chimney Check to make sure the chimney is clear and clean. E. Chimney not long enough The minimum system height is 15 feet (4,6 m). The chimney must extend at least 3 feet (915 mm) above its point of contact with the roof and at least 2 feet (0.6 m) higher than any roof or wall within 10 feet (3 m) of it. When installed with offsets, the minimum system height is as per Table 2. Additional height will increase draft and will decrease the tendency to smoke. F. Poor chimney draft With no fire, there should be sufficient draft to exhaust cigarette smoke introduced at the bottom of the throat. Chimneys installed against an outside wall without protection may generate back draft problems which will cause start‐up problems. To prevent this, when you light a fire make sure you use small pieces of really dry wood and keep your glass door closed for the first 15 minutes. Reload your unit a few times with kindling before putting large pieces of cordwood. IMPORTANT NOTES a. Do not burn coal. The sulphur in coal will corrode the firebox. b. Do not allow the wood to smoulder or burn without flame, since this will produce excessive creosote in the unit. c. The exhaust damper and air intake control should be always in the open position when the fireplace is in use. ...
A. Initially inspect the chimney system weekly. From this, you will learn how often it will be necessary to clean your chimney. B. Have your chimney cleaned by a qualified chimney sweeper. If you wish to clean it yourself, we recommend using a stiff plastic or non‐metallic brush. If a metal brush is used, its size should be slightly smaller than the flue to avoid damaging the chimney. Do not use a brush that will scratch the stainless steel interior of the chimney. C. Do not expect chemical cleaners to keep your chimney clean. The rain cap can be removed for inspection and/or cleaning of the chimney. ...
2.3.5 Refractory Panel Replacement WARNING: DO NOT USE THE FIREPLACE WITH A BROKEN OR MISSING REFRACTORY PANEL. When replacing the refractory panels, it is possible that the insulation paper behind them is detached from the walls of firebox. You must properly position the insulation paper or get a new one from your dealer before putting the new refractory panels. To replace the refractory panels of your FP1LM Manoir fireplace, follow the steps bellow: 1‐ Using a ratchet key with a 7/16” (12 mm) socket, remove the 4 screws (B) holding up the andiron (A). ...
Page 48
3‐ Remove the two panel holders (D) and the refractory panels (E) and (F). 4‐ Remove the back refractory panel (G). To install new refractory panel, follow the above steps in reverse. 48 FP1LM Manoir ‐ Installation and Operation Manual ...
Location Length Dimensions Around each glass 48 5/8" (124 cm) “U” shaped Both glasses used in the FP1LM Manoir are 5 mm thick of dimension: 18" x 15 5/16" and tested to reach temperatures up to 1,400 °F. If the glass breaks, it must be replaced with one having the same specification. Contact your Valcourt dealer to obtain a genuine replacement part (see “replacement parts”, in appendix to get the proper part number). 49 FP1LM Manoir ‐ Installation and Operation Manual...
WARNING: TEMPERED GLASS OR ORDINARY GLASS WILL NOT WITHSTAND THE HIGH TEMPERATURES OF THE FP1LM MANOIR. 2.3.7 Plated Finish Maintenance If your appliance has a plated finish, use a metal polish and a soft cloth to clean it. Do not use abrasives such as steel wool, steel pads or an abrasive cleaner for they may scratch the finish. 2.3.8 Glass Care – Cleaning To clean the glass, there are a number of specially designed cleaners. Your authorized Valcourt dealer can recommend a suitable cleaner which is available in your area. Regular household glass cleaners will not clean creosote and they usually contain ammonia that may stain the glass permanently. WARNING: ONLY WASH THE GLASS WHEN IT’S COLD. WARNING: DO NOT USE ABRASIVES SUCH AS STEEL PADS, STEEL WOOL OR OVEN CLEANER AS THEY ...
APPENDIX 1: OPTIONAL HOT AIR DISTRIBUTION KIT INSTALLATION (AC01375, AC01376 OR AC01340) Different hot air distribution systems can be installed with the FP1LM Manoir: Hot air gravity kit ‐ Traditional style (AC01375) Hot air gravity kit ‐ Modern style (AC01376) Forced air kit (AC01340) Hot air gravity kit ‐ Traditional style (AC01375) The kit includes: 2 x hot air outlets (grilles (A) and frames (B)); 2 x 90 elbows (C); 6 x steel brackets (D) with fastening screws (E) and self‐tapping screws (F) Parts not included in the kit: 2x 8” rigid ducting (G) 51 FP1LM Manoir ‐ Installation and Operation Manual...
Page 52
DIMENSIONS OF HOT AIR OUTLET FRAME WITH ELBOW DIMENSIONS OF HOT AIR OUTLET DECORATIVE GRILLE WITH ELBOW The safety rules and installation procedures for both AC01375 and AC01376 hot air ducting gravity kits are the following: Minimum height* 68" (1.7 m) Minimum distance from ceiling: 12" (30 cm) Maximum length 10' (3m) *The minimum height of the hot air ducting must be measured from the floor to the top of the hot air grilles. 52 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 53
The hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more heat out of the higher grilles. 53 FP1LM Manoir ‐ Installation and Operation Manual...
Page 54
Hot air gravity kit ‐ Modern style (AC01376) L’ensemble comprend : Decorative plate (A) Adjustable frame (B) Heat distribution box (C) 6x steel brackets (D) with fastening screws (E) and self‐tapping screws (F) 2x Finishing cap assemblies (H) AND (J) 2x Fastening screws (I) Parts not included in the kit: 2x 8” rigid ducting (G) 54 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 55
DIMENSIONS OF HEAT DISTRIBUTION BOX: 35" 889mm 38" 965mm 15 3/4" 400mm 5" 127mm 55 FP1LM Manoir ‐ Installation and Operation Manual...
Page 56
DIMENSIONS OF ADJUSTABLE DECORATIVE PLATE: 34 7/8" 886mm 37" 940mm DIMENSIONS OF ASSEMBELED HEAT DISTRIBUTION BOX AND ADJUSTABLE DECORATIVE PLATE: 38" 965mm 56 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 57
The duct system must be installed respecting the following: 1. It is recommended to wear gloves to perform this procedure. For either AC01375 or AC01376, remove the plates closing up the 8" dia. holes on top of the fireplace. Then, cut and remove the insulation in order to obtain two 8" dia. openings. Then, remove the plates closing up the 8" dia. holes inside the fireplace. For AC01375 installation: 1. Secure the 6 steel brackets (D) with 6 screws provided (E) on top of the fireplace (3 for each ducting). ...
Page 58
3. Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole size for the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm). 4. The maximum number of elbows in a run of duct is two. 5. Maintain at least 10" (254 mm) clearance from the outlet grille framing to a combustible ceiling, side wall or mantel. 6. When passing through a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be in accordance with the duct manufacturer’s instructions. 58 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 59
7. Do not connect the hot air ducts to a central heating system. Malfunction of the heating system’s fan will cause the fireplace to overheat. 8. Do not use insulated flexible ducts as they may overheat. 9. Do not use tees or any other components than the ones specifically listed here. 10. All ducts must extend upwards or horizontally. Never route the ducting downwards. 11. The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings. 12. Always install the two outlet grilles when using the hot air outlet kit and blocking the upper louver of the fireplace. 59 FP1LM Manoir ‐ Installation and Operation Manual...
Page 60
For AC01376 installation: 1. Secure the 6 steel brackets (D) with 6 screws provided (E) on top of the fireplace (3 for each ducting). Insert the ducting (G) (not provided) into each opening and secure it in place using the steel brackets (D) installed previously with 6 other self‐tapping screws provided (F). 2.
Page 61
Central Forced Air Kit (not tested to EPA Standards) (AC01340) The knock‐outs provided on the back and on the sides of the FP1LM allow the connection of insulated flexible pipe which enables you to heat adjacent rooms up to 50 feet from the fireplace. This HVAC type pipe must comply with ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F. ...
APPENDIX 2 : BLOWER MAINTENANCE OR REPLACEMENT 1. Open the bottom louver (A). 2. Cut the Tie wrap (B) 62 FP1LM Manoir ‐ Installation and Operation Manual ...
Page 63
3. Lift the blower (C) located under the firebox towards the back. Turn 90° to pull out. 4. Unplug the blower’s electric wires (D) and (E). Repeat the steps in reverse order to reinstall the fan. 63 FP1LM Manoir ‐ Installation and Operation Manual...
Page 64
Blower connection Have the wiring installed by a qualified electrician. Connect the wires from the power outlet to the terminal block, making sure that the white wire matches the white wire on the terminal. Connect the black wire with the black wire of the terminal block. The ground (green or skinned wire) must be attached to the fireplace metal frame. ...
APPENDIX 3: EXPLODED DIAGRAM AND PARTS LIST 65 FP1LM Manoir ‐ Installation and Operation Manual...
Page 66
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrade or availability. Contact an authorized dealer to obtain any of these parts. Never use substitute materials. Use of non‐approved parts can result in poor performance and safety hazards. # Item Description Qty ...
Page 67
# Item Description Qty 39 22161 FRONT REFRACTORY PANEL 1 40 22160 BOTTOM REFRACTORY PANEL 1 41 VA7070 CAST IRON ANDIRON 2 42 30109 BOLT HEX 1/4 ‐ 20 X 1" 4 43 AC01375 HOT AIR GRAVITY KIT ‐ TRADITONAL KIT 1 44 49066 90 DEGREE X 8" 26Ga. GALVANISED ELBOW 2 45 30640 GAKLVANISED BOX FOR AIR GRAVITY KIT 8" 2 46 30540 GRAVITY AIR KIT GRILL 2 47 AC01376 HOT AIR GRAVITY KIT ‐ MODERN STYLE 1 ...
VALCOURT LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Products covered under this warranty must have been manufactured after the revision date indicated below. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your VALCOURT dealer. This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, or venting problems are not covered by this warranty. This warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by the use of ...