Valcourt FP1LM Manoir Installation And Operation Manual

Qualified clean burning decorative fire place
Table of Contents

Advertisement

Installation And Operation Manual 
U.S. EPA Low Mass Wood‐burning 
Fireplace voluntary program phase 2 emission level 
qualified model
 
This  manual  is  available  for  free  download  on  the  manufacturer's  web  site.  It  is  a  copyrighted  document. 
Re‐sale  is  strictly  prohibited.  The  manufacturer  may  update  this  manual  from  time  to  time  and  cannot  be 
responsible for problems, injuries, or damages arising out of the use of information contained in any manual 
obtained from unauthorized sources.
 
 
Printed in Canada 
 
 
www.valcourtinc.com
Stove Builder International Inc. 
250 rue Copenhague, Saint‐Augustin‐de‐Desmaures (Quebec), 
Canada,  G3A 2H3  Tel.: (418) 878‐3040    Fax: (418) 878‐3001 
READ AND KEEP THIS MANUAL FOR REFERENCE 
FP1LM Manoir
 
Safety tested according to ULC S610
Manufactured by: 
 
Qualified Clean Burning
Decorative Fireplace
and UL 127 Standards by Intertek 
 
 
 
45721A 
17‐09‐2014 

Advertisement

Table of Contents
loading

Summary of Contents for Valcourt FP1LM Manoir

  • Page 1 FP1LM Manoir Qualified Clean Burning Decorative Fireplace   Installation And Operation Manual      U.S. EPA Low Mass Wood‐burning  Safety tested according to ULC S610 and UL 127 Standards by Intertek  Fireplace voluntary program phase 2 emission level  qualified model       www.valcourtinc.com Manufactured by:  Stove Builder International Inc.  250 rue Copenhague, Saint‐Augustin‐de‐Desmaures (Quebec),  Canada,  G3A 2H3  Tel.: (418) 878‐3040    Fax: (418) 878‐3001    This  manual  is  available  for  free  download  on  the  manufacturer’s  web  site.  It  is  a  copyrighted  document.  Re‐sale  is  strictly  prohibited.  The  manufacturer  may  update  this  manual  from  time  to  time  and  cannot  be  responsible for problems, injuries, or damages arising out of the use of information contained in any manual ...
  • Page 2   THANK YOU FOR CHOOSING THIS VALCOURT FIREPLACE  As one of North America’s largest and most respected wood stove and fireplace manufacturers, VALCOURT  takes  pride  in  the  quality  and  performance  of  all  its  products.  We  want  to  help  you  get  maximum  satisfaction as you use this product.   In  the  pages  that  follow  you  will  find  general  advice  on  wood  heating,  detailed  instructions  for  safe  and ...
  • Page 3: Table Of Contents

      PART A – INSTALLATION ............... 5   Safety Information ..........................5     1.1.1 Regulations Covering Fireplace Installation ..................7     General Information..........................7     1.2.1 FP1LM Manoir Wood Fireplace Specifications  .................7     1.2.2 The Benefits of EPA Voluntary Emission Program «Low Mass» Phase II  ........ 10     Fireplace Installation  ......................... 10     1.3.1 Installation of a Gas Log Set ...................... 10     1.3.2 Locating the FP1LM Manoir Wood Fireplace ...
  • Page 4 Appendix 1: Optional Hot Air Distribution Kit Installation (AC01375, AC01376 or AC01340) ............. 51   Appendix 2 : Blower Maintenance or Replacement ......62   Appendix 3: Exploded Diagram and Parts List ........65   VALCOURT LIMITED LIFETIME WARRANTY ........68     REGISTER YOU WARRANTY ONLINE  To receive full warranty coverage, you will need to show evidence of the  date you purchased your unit. Keep your sales invoice.  We also  recommend that you register your warranty online at ...
  • Page 5: Part A - Installation

      PART A – INSTALLATION   THE  INFORMATION  GIVEN  ON  THE  CERTIFICATION  LABEL  AFFIXED  TO  THE  APPLIANCE  ALWAYS  OVERRIDES  THE  INFORMATION  PUBLISHED,  IN  ANY  OTHER  MEDIA  (OWNER’S  MANUAL,  CATALOGUES,  FLYERS, MAGAZINES AND/OR WEB SITES).  1.1 Safety Information  CAUTION:   NEVER  USE  GASOLINE,  GASOLINE‐TYPE  LANTERN  FUEL,  KEROSENE,  CHARCOAL  LIGHTER  FLUID OR SIMILAR LIQUIDS TO START OR ‘‘FRESHEN UP’’ A FIRE IN THIS FIREPLACE. KEEP  ALL SUCH LIQUIDS WELL AWAY FROM THE FIREPLACE AT ALL TIMES.  CAUTION: ...
  • Page 6   CAUTION:  OPERATE ONLY WITH GLASS DOORS FULLY CLOSED OR FULLY OPEN WITH MECHE DOORS  ALWAYS CLOSED. IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT  OF  THE  OPENING,  CREATING  RISKS  FROM  BOTH  FIRE  AND  SMOKE.  NEVER  LEAVE  THE  FIREPLACE UNATTENDED WHEN IN USE.  WARNING:  THIS  FIREPLACE  HAS  BEEN  TESTED  FOR  USE  WITH  OPEN  DOORS  IN  CONJUNCTION  WITH  MECHE  DOORS  ALWAYS  CLOSED.  THE  MECHE  DOORS  MAY  BE  OPENNED  ONLY  DURING  LIGHTING ...
  • Page 7: Regulations Covering Fireplace Installation

      1.1.1 Regulations Covering Fireplace Installation  When  installed  and  operated  as  described  in  these  instructions,  the  FP1LM  Manoir  wood  fireplace  is  suitable for use as a fireplace appliance in residential installations.   In  Canada,  the  CSA  B365  Installation  Code  for  Solid  Fuel  Burning  Appliances  and  Equipment  and  the  CSA  C22.1 Canadian National Electrical Code are to be followed in the absence of local code requirements. In  the USA, the NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel‐Burning Appliances and the  ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code requirements.  NOTE:    The Fireplace is not approved for use with a so‐called “positive flue connection” to the clay tile of  a masonry chimney. ...
  • Page 8              8  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 9                 9  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 10: The Benefits Of Epa Voluntary Emission Program «Low Mass» Phase Ii

        1.2.2 The Benefits of EPA Voluntary Emission Program «Low Mass» Phase II  In  the  past,  most  conventional  masonry  and  low‐mass,  factory‐built  fireplaces  were  not  efficient  at  producing  usable  heat.  Typically,  over  90  percent  of  the  heat  generated  by  a  fireplace  was  lost  out  the  chimney. In addition, many of these fireplaces were sources of smoke, indoors and out.  In 2009, the US Environmental Protection Agency (EPA) initiated a voluntary program for manufacturers of  decorative wood burning fireplaces to encourage manufacturers to produce clean wood‐burning appliances  that  reduce  air  pollution.  Under  the  U.S.  EPA  Low  Mass  Fireplace  Voluntary  Program,   cleaner  burning  fireplaces are ones that qualify for the Phase I emission levels of 7.3 g/kg (approximately 57 percent cleaner ...
  • Page 11: Locating The Fp1Lm Manoir Wood Fireplace

      1.3.2 Locating the FP1LM Manoir Wood Fireplace  A. The best location to install your fireplace is determined by considering the location of windows, doors,  and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the  hearth extension and the mantel, and taking into consideration the location of the outside air kit and  chimney.  If  possible,  you  should  choose  a  location  where  the  chimney  will  pass  through  the  house  without  cutting  floor  or  roof  rafters.  Also  choose  a  location  that  allows  installing  the  least  amount  of  offsets in the chimney. ...
  • Page 12       MINIMUM  CLEARANCES  MEASUREMENTS  A  72" (1829 mm) minimum  E  2" (51 mm)  B  12" (305 mm) maximum     12  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 13       13  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 14   In the case where (F) would be equal to 4", it is suggested that the sheet metal between the base of the  fireplace and floor be in one piece.      In the case where the fireplace is installed directly on the floor the joint between the hearth extension and  the  fireplace  (E)  must  also  be  protected  by  a  non‐combustible  material.  For  example,  a  sheet  metal  (not  included).  Note that the floor under of the fireplace should match or exceed the height of the floor protection.   14  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 15       MINIMUM MEASUREMENT  E  2" (51 mm)    A noncombustible floor protection must be installed in front of the unit. For more details see Section 1.3.3:  Minimum Heart Extension Requirements. The use of an R value is convenient when more than one material  is going to be used in the hearth extension to cover the combustible surface. This is because R values are  additive, whereas K values are not. To find the corresponding R factor to use for some selected materials,  please see Thermal Characteristics of Common Floor Protection Materials table.  CAUTION: DO NOT LEAVE CARPET UNDER THE FLOOR PROTECTION IN FRONT OF THE FIREPLACE    15  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 16: R-Value Calculations

      1.3.2.2 R‐Value Calculations  There  are  two  ways  to  calculate  the  R  factor  of  the  floor  protection.  First,  by  adding  the  R‐values  of  the  proposed materials or if some K and thickness values are given, by converting them to R values.  To calculate the R factor for a composite floor protection made of a combination of alternative materials,  simply add the R‐values of those materials. If the result is equal to or larger than the required R value, the  combination  is  acceptable.  For  R‐values  of  some  selected  materials,  see  Table  Thermal  Characteristics of  Common Floor Protection Materials.  Example:  ...
  • Page 17: Minimum Heart Extension Requirements

      Thermal Characteristics of Common Floor Protection Materials*  MATERIAL  CONDUCTIVITY (k)  RESISTANCE  (R) PER INCH  PER INCH  THICKNESS  ® Micore  160  0.39  2.54  ® Micore  300  0.49  2.06  ® Durock   1.92  0.52  ® Hardibacker   1.95  0.51  ® Hardibacker  500  2.3  0.44  ® Wonderboard   3.23  0.31  Cement mortar  5.00  0.2  Common brick ...
  • Page 18       CLEARANCES  A  16" (406 mm)  B  46" (1168 mm)  C  8" (203 mm)      18  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 19: Framing, Facing, Mantel, And Combustible Shelf

      1.3.4 Framing, Facing, Mantel, and Combustible Shelf  1.3.4.1 Framing  The  construction  of  the  framing,  facing,  and  mantel  must  be  in  accordance  with  the  standards  and  the  following illustrations:  A. Frame the fireplace using 2" × 3" (5 cm x 8 cm) or heavier lumber.  WARNING:  COMBUSTIBLE  FRAMING  MATERIAL  CANNOT  BE  USED  IN  THE  SPACE  DIRECTLY  ABOVE  THE  FIREPLACE,  EXCEPT  FOR  THE  STUDS  ABOVE  THE  FACING  THAT  SUPPORT  THE  FACING  MATERIAL ...
  • Page 20     Wall finish behind the fireplace’s faceplate installation      CLEARANCES    MEASUREMENTS  A  2" (51 mm)  E*  41 1/8" (1045 mm)  B*  6 7/8" (175 mm)  F*  25 1/2" (648 mm)  C*  72" (1829 mm) minimum  G  1 3/8" (35 mm) MAX    D*  5 1/2" (140 mm)    *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.   20  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 21   See Section 1.3.5: Fresh Air Intake Kit for fresh air kit (K) and Appendix 1: Optional Hot Air Distribution Kit  Installation (AC01375, AC01376 or AC01340) for the different hot air distribution kits (L) installation.  Fresh air intake kit or forced air kit installation     LEGEND  Combustible material allowed in  this area  Non‐combustible material only in  this area    MINIMUM MEASUREMENTS  MINIMUM MEASUREMENTS    FOR FRESH AIR INTAKE (K)**  FOR FORCED AIR KIT (L)**  H*  12" (305 mm)  18" (457 mm)  J*  12" (305 mm)  18" (457 mm)  *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.  ** The fresh air intake kit may be installed on the left side only and the forced air kit may be installed either  on the sides or on the back.     21  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 22       CLEARANCES**  M*  54 9/16" (1386 mm)  N*  77 3/16" (1961 mm)  *When drywall panels or any other finishing material inside the chase around the fireplace is to be used,  add its thickness to the measurement.  **Values M and N are minimum measurements. They may need to be increased to alloy installation of a  Fresh air intake kit or forced air kit, or depending on the finish material used.      CLEARANCES   A  6" (152 mm) maximum  B  18 1/2" (495 mm) minimum  C  24" (610 mm) minimum  *Measurements for (C) clearances are taken from door opening.   22  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 23: Facing

      1.3.4.2 Facing  Materials  directly  in  the  front  of  the  fireplace,  must  be  non‐combustible  and  have  the  minimum  dimensions shown below.  2. Non‐combustible  materials  such  as  brick,  stone  or  ceramic  tile  may  project  in  front  of  and  onto  the  fireplace decorative frame.  CAUTION:  MATERIALS  MUST  BE  INSTALLED  SO  THAT  THE  FACEPLATE  MAY  BE  REMOVED  AFTER  THE  INSTALLATION. ...
  • Page 24: Compliance Of A Combustible Mantel Shelf

      1.3.4.3 Compliance of a Combustible Mantel Shelf  To ensure compliance of an existing mantel  shelf  or  to  install  a  combustible  mantel  shelf,  refer  to  table  and  figure  in  this  section. For example, a mantel shelf with a  6’’  depth  (152  mm)  ((C)  value)  must  be  installed at least 48" (1219 mm) ((B) value)  above  the  bottom  of  the  fireplace  (see  figure  and  tables  in  this  section).  Different  mantel ...
  • Page 25: Fresh Air Intake Kit

      1.3.5 Fresh Air Intake Kit  During  operation,  the  fireplace  requires  fresh  air  for  combustion  and  draws  air  out  of  the  house.  It  may  starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust fans may compete for air,  causing  negative  pressure  in  the  house,  resulting  in  smoke  entering  the  house  from  the  fireplace.  This  situation is aggravated in modern airtight houses. To overcome this problem, we strongly recommend that  you bring fresh air to the fireplace. Check with local authorities having jurisdiction in your area, it may be  mandatory. ...
  • Page 26                    To  complete  the  installation,  make  a  hole  of  1/4"  to  1/2"  (6  mm  à  13  mm)  bigger  than  the  insulate  pipe  diameter in the outside wall of the house at the chosen location. From outside, place the outside air inlet  cap in the hole (open side down) and fasten the register to the wall, with screws as shown bellow. Place the  insulated pipe over the register tube and over the fireplace outside air connector. At each end, carefully pull  back the insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe using pipe clamps.   For a better seal, you may also use aluminum tape.  Wrap the tape around the joint between the flexible  pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in  place using aluminum tape.                     26  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 27: Faceplate Installation Va1Fe05 Or Va1Fe06 (Sold Separately)

        1.3.6 Faceplate Installation VA1FE05 or VA1FE06 (Sold Separately)  In order to perform installation of VA1FE05 or VA1FE06 faceplate, refer to Installation manual included in  the faceplate kit.      VA1FE05  VA1FE06  Façade moderne ‐ noir métallique  Façade à bandes étroites ‐ noir métallique      27  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 28: The Use Of The Fire Screen

      1.3.7 The Use of the Fire Screen  To take advantage of mesh doors, the glass doors can be retracted toward the inside of fireplace. Note that  the mesh door may be removed for cleaning purposes, but must always be in place and closed when the  fireplace is in use, even if the glass doors are closed.  OPERATE  ONLY  WITH  GLASS  DOORS  FULLY  CLOSED  OR  FULLY  OPEN  WITH  MECHE  DOORS  ALWAYS  CLOSED.  IF  DOORS  ARE  LEFT  PARTLY  OPEN,  GAS  AND  FLAME  MAY  BE  DRAWN  OUT  OF  THE  OPENING,  CREATING  RISKS  FROM  BOTH  FIRE  AND  SMOKE.  NEVER  LEAVE  THE  FIREPLACE  UNATTENDED  WHEN  IN  USE. ...
  • Page 29: Venting System (Chimney And Chimney Connector)

      1.4 Venting System (Chimney and Chimney Connector)  1.4.1 General Information   The  venting  system  is  the  engine  that  drives  your  wood  heating  system.  Even  the  best  fireplace  will  not  function safely and efficiently as intended if not connected to a suitable chimney. The heat in the flue gases  that pass from the fireplace to the chimney is not wasted heat. This heat is what the chimney uses to make  the draft that draws in combustion air and keeps the combustion gases within the fireplace. You can think  of heat in the flue gas as the fuel the chimney uses to make draft.  1.4.2 Suitable Chimneys  This wood fireplace may be connected to either a factory‐built metal or a masonry chimney. Whether metal  or masonry, the chimney must have a number of characteristics to be  suitable. To be suitable, a factory‐ built metal chimney must comply with UL 103HT (U.S.A.), ULC S629 (Canada), ULC S‐604 (Canada) or UL S‐ 610  (U.S.A).  Factory‐built  chimneys  are  tested  as  a  system  with  all  the  necessary  components  for  installation. The instructions provided with the chimney by its manufacturer are the only reliable source of ...
  • Page 30   TABLE 1 ‐ LISTED CHIMNEYS FOR YOUR FP1LM MANOIR WOOD FIREPLACE  CHIMNEY  BRAND  TYPE  INNER DIAMETER  MANUFACTURER  Selkirk  CF Sentinel (CF)  2” Solid Pack  8" (20 cm)  Selkirk  Super Pro 2100 (ALT)  2” Solid Pack  8" (20 cm)  Selkirk  Super Vent 2100 (JM)  2” Solid Pack  8" (20 cm)  Security Chimney  ASHT+  1” Solid Pack  8" (20 cm)  Security Chimney  S‐2100 +  2” Solid Pack  8" (20 cm)  Simpson Dura Vent  Dura Tech  1” Solid Pack  8" (20 cm)  Simpson Dura Vent  Dura Plus HTC  2” Solid Pack  8" (20 cm)  Simpson Dura Vent  Dura Plus  AC Triple Wall  8" (20 cm)  ICC  Excel 2100 ...
  • Page 31: Chimney Installation Notes

      1.4.3 Chimney Installation Notes  1. If  possible,  install  an  interior  chimney  as  it  will  provide  better  performance.  In  areas  with  continuous  temperatures below 18 C (0 F), the use of an exterior chimney increases the likelihood of operating  problems such as low draft, high rate of creosoting, and poor start‐up characteristics. Exterior chimneys  are also prone to down‐drafting and flow reversal. Installations, which are located on lower floors in the  house,  such  as  in  a  basement,  in  combination  with  outside  chimney,  are  especially  prone  to  flow  reversal.  2.
  • Page 32     7. Deviations should be avoided whenever possible, especially the most pronounced. Each deviation adds  some restriction to the chimney system and may lead to draft problems.  8. If  the  chimney  extends  higher  than  5  ft.  (1.5  m)  above  its  point  of  contact  with  the  roof,  it  must  be  secured using a roof brace.  9. A  rain  cap  must  be  installed  on  top  of  the  chimney.  Failure  to  install  a  rain  cap  may  cause  corrosion  problems. ...
  • Page 33: Chimney Installation Instructions

      1.5 Chimney Installation Instructions  Always  refer  to  the  chimney  manufacturer’s  Installation  manual  to  ensure  a  safe  installation.  Some  non‐ illustrated parts may be required.  1.5.1 Examples of Typical Chimney Installation  To  insure  a  good  draft,  it  is  recommended  to  have  a  length  of  18  A  inches  from  the  top  of  the  unit  to  the  first ...
  • Page 34     Direct installation  Exterior offset installation   34  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 35         Interior offset installation  Connection to a masonry chimney  1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb bob to  line up the center of the holes. Make sure that the size of the floor and ceiling holes are in accordance  with the chimney manufacturer’s instructions.  2. From below, install a firestop (B) supplied by the chimney manufacturer in each ceiling/floor separation  through which the chimney will pass. At the attic level, install a radiation shield from above (D).  3. Follow  the  chimney’s  manufacturers’  instructions  and  place  the  first  chimney  length  on  the  fireplace.  For  all  chimneys,  you  must  use  an  anchor  plate  (A)  supplied  by  the  chimney  manufacturer  before   ...
  • Page 36   installing the first chimney length. Continue installing chimney lengths making sure to lock each length  in place.   4. Every  time  the  chimney  passes  through  a  ceiling  or  a  wall, install  the  appropriate  firestop.  When  you  reach the desired height, install the roof support (not illustrated). (Refer to instructions included with  the support).  5. Then, put the roof flashing (E) in place and seal the joint between the roof and the flashing with roofing  pitch. For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles.  Nail the flashing to the roof, using roofing nails.  6. Place the storm collar (F) over the flashing, and tighten it with the bolt supplied. Finally, seal the joint  between the storm collar and the chimney, using silicone caulking.  7. Install the chimney cap (G).  8. When  a  ventilated  roof  flashing  is  installed,  precautions  are  to  be  taken  not  to  caulk  or  seal  the  ventilating openings. ...
  • Page 37       THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED  NOTE: THE FLOOR AND WALLS BELOW THE ATTIC MUST BE INSULATED USING THE SAME INSULATION.    37  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 38: Offset Chimney Installation

      1.5.2 Offset Chimney Installation  TABLE 2 – THE MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS  Fireplace model  FP1LM MANOIR WOOD FIREPLACE  Chimney model  All models listed in Table 1  Vertical installation  15 ft. (4.5 m)  Two (2) elbows  15 ft. (4.5 m)  Four (4) elbows  17 ft. (5.2 m)  After reaching the location requiring the elbow, proceed as follows:  1. To insure a good draft, it is recommended, but non‐mandatory, to have a length of 18 inches (457 mm)  from the top of the unit to the first offset. Install the first elbow; turn it in the required direction. Secure  it  to  the  chimney  according  to  the  chimney  manufacturer’s  instructions.    In  many  cases,  it  is  recommended to secure connections with three (3) ½" (12 mm) metal screws.  2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together  according to the chimney manufacturer’s instructions.  In many cases, it is recommended to use three  (3)  ½"  (12  mm)  metal  screws.  If  the  offset  length  is  made  of  two  (2)  chimney  lengths  or  more,  many  chimney ...
  • Page 39: Chimney Support Installation

        A  INSULATED WALL RADIATION SHIELD  B  GYPSUM BOARD  C  INSULATED WALL    1.5.4 Chimney Support Installation  1.5.4.1 Universal Roof Support  This support has three possible uses:  1. It must be used on a roof to support the chimney.  2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.  3. It may be used on a floor, ceiling or roof as a supplementary support.  For  roof  support  installation,  refer  to  the  instructions  provided  with  the  support  by  the  chimney  manufacturer.  Many manufacturers will provide the maximum height of chimney that can be supported by  the support. Make sure you respect those parameters.    39  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 40: Universal Offset Support

      1.5.4.2 Universal Offset Support  This  support  is  used  to  support  the  chimney  above  an  offset.  When  the  chimney  offset  is  used  to  pass  through a wall, this support may be used on the wall to support the chimney. For offset support installation,  refer to the instructions provided with the support by the chimney manufacturer.  Many manufacturers will  provide  the  maximum  height  of  chimney  that  can  be  supported  by  the  support.  Make  sure  you  respect   ...
  • Page 41   Follow these steps:  1. Position  the  fireplace  in  its  location.  Temporarily  install  the  elbow  or  chimney section (A) on the top of the  fireplace and, using a level, mark with  an  oval  the  location  where  the  flue  liner will enter the masonry chimney.  2. In the middle of the oval, drill a hole in  the masonry chimney at 45 or 30.  3. Increase  the  size  of  the  hole  until  a  45  or  30  insulated  liner  adapter  (B)  can be easily slipped through. ...
  • Page 42: Part B - Operation And Maintenance

      PART B ‐ OPERATION AND MAINTENANCE  2.1 Fuel  The  FP1LM  MANOIR  is  designed  to  work  best  when  fuelled  with  seasoned  cordwood.  Use  solid  wood  or  processed solid fuel fire logs only. Hardwoods are preferred to softwoods since the energy content of wood  is  relative  to  its  density.  Hardwoods  will  result  in  a  longer  burning  fire  and  less  frequent  refuelling.  A  moisture content of 15% to 20% (seasoned) is recommended. Wood that has been cut and split and let to ...
  • Page 43: Operating The Fp1Lm Manoir Wood Fireplace

      2.2 Operating the FP1LM Manoir Wood Fireplace  CAUTION:  WHEN USING THE DECORATIVE APPLIANCE, THE FIREPLACE DAMPER MUST BE SET IN THE  FULLY OPEN POSITION.  2.2.1 First Fires  Two things will happen as you burn your first few fires; the paint cures and the internal components of the  fireplace are conditioned.   As the paint cures, some of the chemicals vaporize. The vapors are not poisonous, but they do smell bad.  Fresh paint fumes can also cause false alarms in smoke detectors. So, when you first light your fireplace, be  prepared  by  opening  doors  and/or  windows  to  ventilate  the  house.  As  you  burn  hotter  and  hotter  fires,  more of the painted surfaces reach the curing temperature of the paint. The smell of curing paint does not  disappear until you have burned one or two very hot fires.   Burn one or two small fires to begin the curing and conditioning process. Then build bigger and hotter fires  until there is no longer any paint smell from the fireplace. Once the paint smell disappears, your fireplace is  ready for serious heating.  2.2.2 Building a Fire  To start a fire, place several crumpled up balls of newspaper in the firebox behind the andiron. Place small  dry pieces of kindling on top of the paper, criss‐crossing the kindling so that there are air spaces in between.  Open  the  exhaust  damper  fully  and  light  the  newspaper.  Once  the  newspaper  and  the  kindling  are  well  ignited, you may close the glass door for a few minutes so that the firebox and chimney of your fireplace ...
  • Page 44: Air Intake Control And Exhaust Damper

      2.2.4 Air Intake Control and Exhaust Damper  The air intake control (dilution air) and exhaust damper should be in the closed position when there has not  been any wood or embers in the fireplace for a few hours. This will minimize air leakage up the chimney.     A  OPEN position  B  CLOSE position      Air Intake Control  Exhaust Damper  2.2.5 Smoking  Causes and Troubleshooting  Your fireplace has been designed and tested to provide smoke free operation. Occasionally, there may be a  small amount of smoking upon lighting the fire, until the chimney heats up but this should not continue. If  the fireplace continues to smoke it is probably for one of the following reasons:  A. Closed exhaust damper  Make  sure  that  the  exhaust  damper  is  in  the  open  position  (see  Section  2.2.4:  Air  Intake  Control  and  Exhaust Damper).  B.
  • Page 45: Maintaining Your Fp1Lm Manoir Wood Fireplace

      C. Wet wood  Wet or tarred wood will smoulder and smoke instead of burning properly.  D. Dirty or blocked chimney  Check to make sure the chimney is clear and clean.  E. Chimney not long enough  The minimum system height is 15 feet (4,6 m). The chimney must extend at least 3 feet (915 mm) above its  point of contact with the roof and at least 2 feet (0.6 m) higher than any roof or wall within 10 feet (3 m) of  it. When installed with offsets, the minimum system height is as per Table 2. Additional height will increase  draft and will decrease the tendency to smoke.  F. Poor chimney draft  With no fire, there should be sufficient draft to exhaust cigarette smoke introduced at the bottom of the  throat.  Chimneys  installed  against  an  outside  wall  without  protection  may  generate  back  draft  problems  which will cause start‐up problems. To prevent this, when you light a fire make sure you use small pieces of  really dry wood and keep your glass door closed for the first 15 minutes. Reload your unit a few times with  kindling before putting large pieces of cordwood.   IMPORTANT NOTES  a. Do not burn coal. The sulphur in coal will corrode the firebox.  b. Do not allow the wood to smoulder or burn without flame, since this will produce excessive creosote in  the unit.  c. The exhaust damper and air intake control should be always in the open position when the fireplace is  in use. ...
  • Page 46: Dealing With A Chimney Fire

      A. Initially inspect the chimney system weekly. From this, you will learn how often it will be necessary to  clean your chimney.  B. Have  your  chimney  cleaned  by  a  qualified  chimney  sweeper.  If  you  wish  to  clean  it  yourself,  we  recommend using a stiff plastic or non‐metallic brush. If a metal brush is used, its size should be slightly  smaller than the flue to avoid damaging the chimney. Do not use a brush that will scratch the stainless  steel interior of the chimney.  C. Do  not  expect  chemical  cleaners  to  keep  your  chimney  clean.  The  rain  cap  can  be  removed  for  inspection and/or cleaning of the chimney. ...
  • Page 47: Refractory Panel Replacement

      2.3.5 Refractory Panel Replacement  WARNING:  DO NOT USE THE FIREPLACE WITH A BROKEN OR MISSING REFRACTORY PANEL.  When replacing the refractory panels, it is possible that the insulation paper behind them is detached from  the  walls  of  firebox.  You  must  properly  position  the  insulation  paper  or  get  a  new  one  from  your  dealer  before putting the new refractory panels.  To replace the refractory panels of your FP1LM Manoir fireplace, follow the steps bellow:  1‐ Using  a  ratchet  key  with  a  7/16”  (12  mm)  socket,  remove  the  4  screws  (B)  holding up the andiron (A). ...
  • Page 48   3‐ Remove the two panel holders (D) and  the refractory panels (E) and (F).      4‐ Remove the back refractory panel (G).  To install new refractory panel, follow the  above steps in reverse.         48  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 49: Replacing The Glass Gasket And/Or The Glass

      Location  Length  Dimensions  Around each glass  48 5/8" (124 cm)  “U” shaped    Both glasses used in the FP1LM Manoir are 5 mm thick of dimension: 18" x 15 5/16" and tested to reach  temperatures  up  to  1,400  °F.    If  the  glass  breaks,  it  must  be  replaced  with  one  having  the  same  specification. Contact your Valcourt dealer to obtain a genuine replacement part (see “replacement parts”,  in appendix to get the proper part number).    49  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 50: Plated Finish Maintenance

    WARNING: TEMPERED GLASS OR ORDINARY GLASS WILL NOT WITHSTAND THE HIGH TEMPERATURES OF  THE FP1LM MANOIR.  2.3.7 Plated Finish Maintenance  If your appliance has a plated finish, use a metal polish and a soft cloth to clean it. Do not  use abrasives  such as steel wool, steel pads or an abrasive cleaner for they may scratch the finish.  2.3.8 Glass Care – Cleaning  To clean the glass, there are a number of specially designed cleaners. Your authorized Valcourt dealer can  recommend  a  suitable  cleaner  which  is  available  in  your  area.  Regular  household  glass  cleaners  will  not  clean creosote and they usually contain ammonia that may stain the glass permanently.   WARNING:  ONLY WASH THE GLASS WHEN IT’S COLD.  WARNING:  DO  NOT  USE  ABRASIVES  SUCH  AS STEEL  PADS,  STEEL  WOOL  OR  OVEN  CLEANER AS  THEY ...
  • Page 51: Appendix 1: Optional Hot Air Distribution Kit Installation (Ac01375, Ac01376 Or Ac01340)

      APPENDIX  1:  OPTIONAL  HOT  AIR  DISTRIBUTION  KIT  INSTALLATION  (AC01375,  AC01376 OR AC01340)  Different hot air distribution systems can be installed with the FP1LM Manoir:   Hot air gravity kit ‐ Traditional style (AC01375)   Hot air gravity kit ‐ Modern style (AC01376)   Forced air kit (AC01340)  Hot air gravity kit ‐ Traditional style (AC01375)  The kit includes:  2 x hot air outlets (grilles (A) and frames (B));  2 x 90  elbows (C);  6 x steel brackets (D) with fastening screws (E) and self‐tapping screws (F)  Parts not included in the kit:  2x 8” rigid ducting (G)      51  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 52   DIMENSIONS OF HOT AIR OUTLET FRAME WITH ELBOW    DIMENSIONS OF HOT AIR OUTLET DECORATIVE GRILLE WITH ELBOW    The safety rules and installation procedures for both AC01375 and AC01376 hot air ducting gravity kits are  the following:  Minimum height*  68" (1.7 m)   Minimum distance from ceiling:  12" (30 cm)  Maximum length   10' (3m)  *The  minimum  height  of  the  hot  air  ducting  must  be  measured  from  the  floor  to  the  top  of  the  hot  air  grilles.    52  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 53   The hot air grilles can be installed in the same room as the fireplace, or one or both of the grilles can be  installed in adjacent or upper rooms. Installing the ducts at different elevations will tend to exhaust more  heat out of the higher grilles.       53  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 54   Hot air gravity kit ‐ Modern style (AC01376)  L’ensemble comprend :  Decorative plate (A)   Adjustable frame (B)  Heat distribution box (C)  6x steel brackets (D) with fastening screws (E) and self‐tapping screws (F)  2x Finishing cap assemblies (H) AND (J)  2x Fastening screws (I)   Parts not included in the kit:  2x 8” rigid ducting (G)     54  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 55   DIMENSIONS OF HEAT DISTRIBUTION BOX:  35"  889mm  38"  965mm  15 3/4" 400mm 5"  127mm    55  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 56   DIMENSIONS OF ADJUSTABLE DECORATIVE PLATE:  34 7/8"  886mm    37" 940mm   DIMENSIONS OF ASSEMBELED HEAT DISTRIBUTION BOX AND ADJUSTABLE DECORATIVE PLATE:  38"  965mm     56  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 57   The duct system must be installed respecting the following:  1. It is recommended to wear gloves to perform this procedure.  For either AC01375 or AC01376, remove  the plates closing up the 8" dia. holes on top of the fireplace. Then, cut and remove the insulation in  order  to  obtain  two  8"  dia.  openings.  Then,  remove  the  plates  closing  up  the  8"  dia.  holes  inside  the  fireplace.     For AC01375 installation:  1. Secure  the  6  steel  brackets  (D)  with  6  screws  provided  (E)  on  top  of  the  fireplace  (3  for  each  ducting). ...
  • Page 58                 3. Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole size  for the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm).  4. The maximum number of elbows in a run of duct is two.  5. Maintain at least 10" (254 mm) clearance from the outlet grille framing to a combustible ceiling, side  wall or mantel.  6. When passing through a combustible wall or floor, a firestop must be installed at the wall or floor  penetration. The hole size must be in accordance with the duct manufacturer’s instructions.     58  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 59     7. Do not connect the hot air ducts to a central heating system. Malfunction of the heating system’s  fan will cause the fireplace to overheat.   8. Do not use insulated flexible ducts as they may overheat.  9. Do not use tees or any other components than the ones specifically listed here.  10. All ducts must extend upwards or horizontally. Never route the ducting downwards.  11. The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent  overheating adjacent ceilings.  12. Always install the two outlet grilles when using the hot air outlet kit and blocking the upper louver of  the fireplace.    59  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 60   For AC01376 installation:  1. Secure  the  6  steel  brackets  (D)  with  6  screws  provided  (E)  on  top  of  the  fireplace  (3  for  each  ducting).  Insert  the  ducting  (G)  (not  provided)  into  each  opening  and  secure  it  in  place  using  the  steel brackets (D) installed previously with 6 other self‐tapping screws provided (F).  2.
  • Page 61   Central Forced Air Kit (not tested to EPA Standards) (AC01340)  The  knock‐outs  provided  on  the  back  and  on  the  sides  of  the  FP1LM  allow  the  connection  of  insulated  flexible pipe which enables you to heat adjacent rooms up  to 50 feet from the fireplace. This  HVAC type  pipe  must  comply  with  ULC  S110  and/or  UL  181,  Class  0  or  Class  1  Standards  and  must  withstand  temperatures up to 250 °F. ...
  • Page 62: Appendix 2 : Blower Maintenance Or Replacement

      APPENDIX 2 : BLOWER MAINTENANCE OR REPLACEMENT    1. Open the bottom louver (A).      2. Cut the Tie wrap (B)     62  FP1LM Manoir ‐ Installation and Operation Manual ...
  • Page 63   3. Lift  the  blower  (C)  located  under  the  firebox  towards  the  back.  Turn  90°  to  pull out.  4. Unplug  the  blower’s  electric  wires  (D)  and (E).  Repeat  the  steps  in  reverse  order  to  reinstall the fan.        63  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 64   Blower connection   Have the wiring installed by a qualified electrician. Connect the wires from the power outlet to the terminal  block,  making  sure  that  the  white  wire  matches  the  white  wire  on  the  terminal.    Connect  the  black  wire  with  the  black  wire  of  the  terminal  block.    The  ground  (green  or  skinned  wire)  must  be  attached  to  the  fireplace metal frame. ...
  • Page 65: Appendix 3: Exploded Diagram And Parts List

      APPENDIX 3: EXPLODED DIAGRAM AND PARTS LIST      65  FP1LM Manoir ‐ Installation and Operation Manual...
  • Page 66   IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove,  please  provide  the  model  number  and  the  serial  number.  We  reserve  the  right  to  change  parts  due  to  technology  upgrade  or  availability.  Contact  an  authorized  dealer  to  obtain  any  of  these  parts.  Never  use  substitute materials. Use of non‐approved parts can result in poor performance and safety hazards.  #  Item  Description  Qty ...
  • Page 67   #  Item  Description  Qty  39  22161  FRONT REFRACTORY PANEL  1  40  22160  BOTTOM REFRACTORY PANEL  1  41  VA7070  CAST IRON ANDIRON  2  42  30109  BOLT HEX 1/4 ‐ 20 X 1"  4  43  AC01375  HOT AIR GRAVITY KIT ‐ TRADITONAL KIT  1  44  49066  90 DEGREE X 8" 26Ga. GALVANISED ELBOW  2  45  30640  GAKLVANISED BOX FOR AIR GRAVITY KIT 8"  2  46  30540  GRAVITY AIR KIT GRILL  2  47  AC01376  HOT AIR GRAVITY KIT ‐ MODERN STYLE  1 ...
  • Page 68: Valcourt Limited Lifetime Warranty

      VALCOURT LIMITED LIFETIME WARRANTY  The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers  brand  new products  only,  which have  not been  altered, modified  nor  repaired  since shipment  from  factory.  Products covered  under this warranty must have been manufactured after the revision date indicated below. Proof of purchase (dated bill of sale),  model name and serial number must be supplied when making any warranty claim to your VALCOURT dealer.    This  warranty  applies  to  normal  residential  use  only.  Damages  caused  by  misuse,  abuse,  improper  installation,  lack  of  maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, or venting problems are  not covered by this warranty.  This  warranty  does  not  cover  any  scratch,  corrosion,  distortion,  or  discoloration.  Any  defect  or  damage  caused  by  the  use  of ...