MAINTENANCE PROCEDURE
11. Push the button of dust indicator.
The yellow piston returns.
Even though the outer element has not been cleaned up to 6 times, if the yellow piston of dust indicator laps
over the red zone (7.5 kPa {0.08 kg/cm
lights up, replace both the inner and outer elements.
METHOD FOR REPLACING AIR CLEANER ELEMENT
1.
Remove clips (1) (4 pieces) and remove cover (2).
2.
Install on-board air cleaner pull-out jig (3) to the narrow
part of outer element (4).
4-18
2
}) soon after the cleaning, or if the air cleaner clogging caution lamp