Fastening Module
The fastening module is an auxiliary part of the waterproof frame. It is used to lock
all the modules on the frame to ensure a sound waterproof effect. Figure 5-23
shows the appearance of a fastening module.
Table 5-4 lists the specifications of these three modules and their functions.

Table 5-4 Specifications of common sealing module

Available diameter
Type
of cables (mm)
3.7 mm to 9.7 mm
A module
(0.15 in. to 0.38 in.)
3.7 mm to 13.5 mm
B module
(0.15 in. to 0.53 in.)
11.5 mm to 22.5 mm
C module
(0.45 in. to 0.89 in.)
Filler module
The filler module is used to fill the space where cables are not routed through
on the frame. Figure 5-22 shows the appearance of a filler module.
Figure 5-22 Filler module
There are two types of filler modules. Table 5-5 lists their differences.

Table 5-5 Filler module specifications

Dimensions (Length x Width
Specifications
5mm x 40mm x 30mm
Type 1
(0.2 in. x 1.6 in. x 1.2 in.)
10mm x 40mm x 30mm
Type 2
(0.4 in. x 1.6 in. x 1.2 in.)
Huawei Technologies Proprietary
Function
Separates optical
fiber and alarm
cables
Separates E1 and
microwave
transmission cables
Separates external
power cables and
PGND cables
x Depth)
5-22
Chapter 5 Installing Cables
Quantity
per cabinet
2
8
9
Quantity per
cabinet
1
3