Ebyte E180-Z5812SX Manual page 33

Tlsr8258 2.4ghz zigbce 3.0 multifunctional soc rf module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
6.6.27 Configure the trust center connection key
Command format for Read:
Command Format
Send: FE 10 38 FF
Reply: FB 38 TrustCentLinkKey
Command format for Configuration:
Command Format
Send: FD 10 38 TrustCentLinkKey FF
Reply: FA 38
TrustCentLinkKey:16Bytes, the default value is the default key of the ZigBee Alliance and its value is
After the device restarts, the configuration takes effect.
Note: Only the connected device holding the same link key (LinkKey) as the trust center (coordinator) can it connect to the network of
the trust center (coordinator), and the trust center (coordinator) transmits the network key to the connected device , The connected
device completes the process of joining the network to obtain the network key for normal communication.
6.6.28 Firmware version instruction parameter
Command format for Read:
Command Format
Send: FE 03 34 FF
Reply: FB 34 FirmwareVersion
Firmware_version: 82 58 00
82 58 means Telink 8258.
00 means the firmware version number
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
Command Example
Send: FE 10 38 FF
Reply: FB 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
Command Example
Send: FD 10 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
FF
Reply: FA 38
0x5A 0x69 0x67 0x42 0x65 0x65 0x41 0x6C
0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39
Command Example
Send: FE 03 34 FF
Reply: FB 34 82 58 01