6.1.5 UART_BAUD_RESET Details
The UART BAUD RESET pin is used to reset the baud rate of the device. It defaults to a high level after power-on. In any mode,
the module serial port parameters will be restored to the default 115200 and 8N1 if the pin is pulled down for more than 1000ms.
6.2 Wireless remote configuration function
The module supports the remote configuration function, which is identified by the two-byte wireless
configuration ID by default as A8 8A. The user can modify the remote configuration ID of the module. When the
module receives the first two bytes of wireless air data as the wireless configuration ID, The module judges that the
data packet is a remote configuration command and executes the operation corresponding to the command. The
data packet will not be output through the serial port. The remote configuration of the dormant terminal needs to
wake up first.
6.3 Function Parameter Description
The module provides a wealth of configurable parameters, which can be used flexibly according to actual
application requirements to construct different forms of networks.
Configuration
Type
PANID
Read/
write
Local
read
network
address
network
read
status
Destination
Read/
network
write
address
Local MAC
read
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
Pins
LINK
WAKE
AUX
ACK
UART_BAUD_RESET
Code Range
0x0000~
PANID is the network identifier of ZIGBEE, used to determine the
0xFFFF
identity of the network to which it belongs. The PANID of all devices in
the same network must be the same. When the terminal or router is
configured as 0xFFFF, it can join any network where the same channel
already exists.
0x0000~
Used to distinguish each node in the network. Each device is in the same
0xFFFF
network. The local network address must be unique. When not joining the
network, the network address of the device is 0xFFFF. After joining, the
device short address is assigned by the coordinator. The coordinator is
fixed as: 0x0000.
0、2、3
Indicates the network status of the current device, including no network,
has successfully joined the network, and there is no parent node.
0x0000~
The current device communication destination (short address) can be
0xFFFF
switched at any time through configuration commands.
64bitMAC
The MAC address assigned by the network of this module cannot be
Interface
PC1
PD3
PB5
PB1
PA1
Functions
E180-Z5812SX User Manual
12