6.6.5 Network PAN_ID
Command format for Read:
Command Format
Send: FE 02 03 FF
Reply: FB 03 pan_id
Command format for Configuration:
Command Format
Send: FD 02 03 pan_id FF
Reply: FA 03
pan_id:
0x0000~0xFFFE fixed network PAN_ID
0xFFFF random network PAN_ID
Note: If the coordinator is configured as 0xFFFF, then PANID is randomly selected to establish a network. Terminals, routing,
etc. can be configured with 0xFFFF to join any PANID network. PANID parameters need to be configured before joining the
network.
6.6.6 Network Short Address:
Command format for Read:
Command Format
Send: FE 02 05 FF
Reply: FB 05 Short_Addr
Short_Addr:2 Byte, Address randomly assigned by the coordinator
6.6.7 MAC Address
Command format for Read:
Command Format
Send: FE 08 06 FF
Reply: FB 06 Mac_Addr
Mac_Addr: 8 Byte
Copyright ©2012–2021, Chengdu Ebyte Electronic Technology Co., Ltd.
Command Example
Send: FE 02 03 FF
Reply: FB 03 FE 5B
Command Example
Send: FD 02 03 FE 5B FF
Reply: FA 03
Command Example
Send: FE 02 05 FF
Reply: FB 05 F6 FA
Command Example
Send: FE 08 06 FF
Reply: FB 06 1F 1C 21 FE
FF 57 B4 14