Operation, Storage And Transportation Requirements; Label; Label Paste Position - NEC N8160-48 User Manual

Ait/external ait
Table of Contents

Advertisement

Operation, Storage and Transportation
Requirements
Operation requirement
Temperature
Humidity
Shelf time
Storage requirement
Temperature
Humidity
Storage condition
Transportation requirement
Temperature
Humidity
Temperature gradient
Transportation condition : Store an AIT data cartridge in a protective case. During transporta-

Label

It is recommended that you should affix a label to each AIT cartridge to associate the AIT data
cartridge with the backup data for easier identification.

Label paste position

: 10 to 45 °C
: 20 to 80 % (The maximum temperature of wet bulb is 26 °C.)
: If an AIT data cartridge is exposed to an environment other than
the operating or storage environment, expose it to the operating
environment for a longer time than the period when it is exposed to
other environment (for 8 hours at maximum) before use. The
temperature gradient is 10 °C/hour.
: 5 to 32 °C
: 20 to 60 % (The maximum temperature of wet bulb is 26 °C.)
: Store an AIT data cartridge in a protective case with cover. You
can place the case horizontally or vertically.
: –40 to 45 °C
: 5 to 80 % (The maximum temperature of wet bulb is 26 °C.)
: 10 °C/hour
tion, pack the case so that force will not apply to the AIT data
cartridge.
AIT Data Cartridge 79

Advertisement

Chapters

Table of Contents
loading

Table of Contents