The minimum vent system for horizontal termination must consist of:
13" to vent center, then straight out the wall (using flex kit)
The maximum vent system consists of:
34' vertical length with 4 - 90° bends and a 20' horizontal length
(measured to center of pipe)
H3
v2
H2
10
OUTDOOR
WALL
MTO-4F
Maximum Vertical vent run:
34' vertical length with a roof termination,
restrictor recommended.
Maximum Horizontal vent run:
34' vertical length with 4 elbows, and
the maximum 20 feet horizontal run.
DIMENSIONS ARE IN INCHES