System Option 3. The system may be configured for use with the following:
System Option 4. The system may be configured for use with the following:
System Option 5.
The system may be configured for use with the following:
is activated.
Rins163 Issue 9
Engineer Code Lock N.V.M Reset: This option allows the control panel programmable
settings to be reverted back to factory default when in Engineer mode only.
Engineer Power Up N.V.M Reset: This allows the control panel programmable settings to be
reverted back to factory default when in User Mode.
Engineer Only System Reset: After an alarm activation the user may disable the siren and
bell only, to reset the system fully the engineer must enter his code.
User System Reset: After an alarm activation any user code will reset the system.
User Omits Disabled: If selected the user is unable to omit zones when setting the panel.
User Omits Enabled: If selected the user is able to omit zones when setting the panel.
Door Chime: If enabled a door bell switch may be used to operate the dual tone at the
keypad / panel (connected to the Push To Set terminals).
Anti-code: If enabled, after an alarm activation the user may disable the siren and bell only, to
reset the system fully the engineer or customer must enter an anti-code. The anti-code is a
randomly generated 5 digit number displayed on the keypad, the number should be given to
who ever holds the anti-code generator, who in turn will give you a 4 digit number which when
entered at the keypad will reset the panel. The engineer as a means of identifying the system
can set the first digit of the anti-code.
Open Zone: When enabled and the panel is unset, any entry/exit, access or immediate zones
will be displayed at the keypad.
Alarm on line fail – STU: when the panel is set, if a line fail occurs the internal and external
alarms will activate and a system fault will be generated.
No alarm on line fail –STU: when the panel is set, if a line fail occurs a system fault will be
generated.
Alarm on line fail – PC: when the panel is set, if a line fail occurs the internal and external
alarms will activate and a system fault will be generated.
No alarm on line fail –PC: when the panel is set, if a line fail occurs a system fault will be
generated.
Alarm Digi Active High: This will switch from 0 to 12V at the alarm digi com output when
the alarm is activated.
Alarm Digi Active Low: This will switch from 12 to 0V at the alarm digi com output when the
alarm is activated.
PA Digi Active High: This will switch from 0 to 12V at the PA digi com output when the PA
PA Digi Active Low: This will switch from 12 to 0V at the PA digi com output when the PA
is activated.
Fire Digi Active High: This will switch from 0 to 12V at the Fire digi com output when the
Fire key is activated.
Fire Digi Active Low: This will switch from 12 to 0V at the Fire digi com output when the
Fire key is activated.
Confirm Digi Active High: This will switch from 0 to 12V at the Confirmed digi com output.
Confirm Digi Active Low: This will switch from 12 to 0V at the Confirmed digi com output.
Page 15