Diamond DC Board ONLY

P/O Adjust Switches #1 - #4

Not used, leave in OFF position.
Power Indicator LEDs
When ON, Indicates AC input power is connected to
operator and functioning normally.
When ON, Indicates low battery power. Charging will
automatically start when operator is able.

Power ON/OFF Switch and 5-Pin Primary Plug for Diamond DC Board

5-Pin Primary Plug:
Connects and disconnects
ALL power to the operator
(AC AND Battery Power).
IMPORTANT:
Batteries will
NOT charge unless plug is
connected into Diamond
DC board.

Battery Replacement When Necessary

Normal battery deterioration will take place over time and batteries will need to be replaced eventually. Remove the 5-Pin Primary Connector
(White Plug) from Diamond DC Board BEFORE replacing the Eagle Battery Pack.
IMPORTANT:
Use only Eagle Battery Pack in your Eagle gate operator.
+
OFF
1
OFF
2
OFF
3
P/O ADJUST
AC POWER
SOLAR
24VAC
POWER
LOW
CHARGER
BATTERY
ON
Power Switch
OFF
SELECT
LIGHT
HEAVY
ACTIVE
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
MH1
REVERSE LOOP NO
REVERSE LOOP NC
OVERLOAD
ONE PASS OFF
ONE PASS ON
OPENING
CLOSING
STOP-REVERSE OFF
STOP-REVERSE ON
ALARM-RESET OFF
ALARM-RESET ON
CLOSE TIMER OFF
CLOSE TIMER ON
TIMER
ERD STATUS
MH2
OFF—ON
PWR FAIL OPERATION
0
1
AUTO OPEN OFF
AUTO OPEN ON
+
POWER FAIL OPEN
POWER FAIL CLOSE
OFF
1
OPEN DELAY MASTER OFF
OPEN DELAY MASTER ON
OFF
2
OPEN DELAY SLAVE OFF
OPEN DELAY SLAVE ON
OFF
3
M/S PHASE
RESET
OFF—ON
P/O ADJUST
REVERSE
LOOP
SHADOW
LOOP
EXIT
OPEN
MH3
MH4
REVERSE
SHADOW
EXIT
FUSE MAX 20A
FUSE MAX 35A
AC POWER
SOLAR
24VAC
POWER
REVERSE LOOP
SHADOW LOOP
EXIT LOOP
#1
RELAY
LOW
CHARGER
BATTERY
ON
RELAY
24VDC
+ –
-24VDC
OPEN
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
MAG LOCK
STOP
POWER 24 VDC
CLOSE
GLOBAL INPUTS
OUTPUTS
When ON, Indicates battery pack is connected to operator
and functioning normally.
When ON, Indicates battery charging is taking place.
ON
Power Switch: Connects and
disconnects the AC input power
ONLY.
IMPORTANT:
OPEN
OPENING CLOSING
CLOSE
LIMIT
LIMIT
NOT disconnect battery power to
GATE STATUS
the operator.
20
5-Pin Primary Connector
20 Amp
#12
#13
#14
SLAVE
MASTER
+ –
+ –
+ –
COMM PORT
AC Input Power Wire
Power switch does
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200 series200-dc-hd200-dc200200-1hp200-dm

Table of Contents