Global Inputs Descriptions; Radio Receiver Connection - Eagle 100 Series Installation & Owner's Manual

Swing gate operators diamond control board or diamond dc control board
Hide thumbs Also See for 100 Series:
Table of Contents

Advertisement

Global Input Descriptions
#2 REVERSE LOOP: Momentary or continuous signal - This input is active
only when the gate is closing or when its fully open, if this input is active.
The close timer is disabled. Vehicle loop detectors and photo sensors
should be connected here. Multiple devices may be connected in parallel.
#3 SHADOW LOOP: Momentary or continuous signal - This input is active
only when the gate is at rest in the fully open position. The input has no
effect on the gate when fully closed or while closing or opening. Continuous
activation will prevent the gate from moving in the close direction. When
the input is removed, normal operation is resumed. The input is intended
for a vehicle loop detector to sense a vehicle in the gate path. Multiple devices may be connected in parallel.
#4 EXIT LOOP: Momentary or continuous signal - Once activated, the gate will fully open. Activation while the gate is closing will cause the
gate to re-open. Continuous activation while the gate is open will disable the close timer from automatically closing the gate.
#5 STOP: Momentary or continuous signal - This function overrides all other signals. Once activated, the gate will immediately stop and wait
for a new command to be given. If the stop input is continuously activated, the gate will not move. A jumper wire has been factory installed in
this input for the operator to function normally. It must be removed ONLY when using the 3-Button Station, see next page.
#6 KEY / KEYPAD:
Close Timer ON - Momentary or continuous signal - Once activated, the gate will fully open. Activation while the gate is closing will cause
the gate to re-open. Continuous activation while the gate is open will disable the close timer from automatically closing the gate.
Close Timer OFF - Momentary input - This function must be released and reentered to be recognized. This input is to be used for
COMMAND OPEN / COMMAND CLOSE applications. The first signal will cause the gate to begin opening. The second signal will close the
gate only when the gate is in the fully open position.
#7 CLOSE: Momentary or continuous signal - Once activated, the gate will fully close. Activation while the gate is opening will cause the gate
to stop. Activating the gate again will close the gate.
#8 EDGE SENSOR: Momentary or continuous signal - This signal is active when the gate is opening and/or closing.
If activated when the gate is OPENING: The gate will stop, pause and reverse in the close direction for 1 1/2 seconds and stop.
Continuous activation will prevent the gate from moving in the opening direction. If the second activation occurs before the limit switch is
activated, the gate will stop and reverse direction for 1 1/2 seconds and stop. Thus activating the ALARM MODE. At this point, the operator
must be manually reset (OFF/ON) before normal operation can resume.
If activated when the gate is CLOSING: The gate will stop, pause and fully re-open. During this mode, the timer to close, reverse loop, exit
loop and phantom loop are disabled. The key/keypad and receiver will cause the gate to close if a second activation occurs before the limit
switch is activated. The gate will stop and reverse direction for 1 1/2 seconds and stop again, thus activating the ALARM MODE. At this
point, the operator must be manually reset (OFF/ON) before normal operation can resume.

Radio Receiver Connection

Radio receiver terminal is mounted on the outside of the control box for easy
installation and is pre-wired for a 3-wire or a 4-wire receiver. The Radio receiver
terminal is wired to the control board #1 as shown below.
3-Wire Receiver
NOTE: Radio Receiver
can be connected to
the master or slave
operator for
master/slave setup.
Radio Receiver
Control Board
Terminal Wires
Connection #1
Black
RELAY
RELAY
24VDC
Red
-24VDC
Orange
Diamond DC Board ONLY
4-Wire Receiver
24V
(24V)
24V
3
3
Wire
RADIO POWER
RELAY
COMMON GROUND
Wire
RADIO POWER
3
2
1
4
3
24V
(24V)
24V
4
4
Wire
RADIO POWER
RELAY
RELAY RET
RET
Wire
RADIO POWER
#1
#2
#3
(24V)
RELAY
COMMON GROUND
2
1
4
(24V)
RELAY
RELAY RET
RET
#4
#5
#6
#7
GLOBAL INPUTS
Jumper Wire
Radio
Receiver
Terminal
3
24V
Wire
RADIO POWER
3
24V
4
Wire
RADIO POWER
#8
(24V)
RELAY
COMMON GROUND
2
1
4
(24V)
RELAY
RELAY RET
RET