CONTROL BOARD ADJUSTMENTS AND WIRING

Feature Selector Switches #1 - #4

The Feature Selector Descriptions:
NOTE: The power MUST be turned OFF before changing the features selector switches.
Switch #1:
Slave/Master - Sets the operator to work as Master or Slave. Single operator
installation MUST be set to MASTER.
Switch #2:
Gate Opening - designates left or right opening direction. See page 12.
Switch #3:
Motor Brake - If the ON position is selected, the gate will stop instantly when
the limit switch is activated. This is useful for uphill/downhill applications and on all
fail-safe operators.
Switch #4:
Close Timer (ON/OFF) - Turns the close timer ON or OFF. See page 14.

Control Board Overview

M/S Phase
DO NOT remove jumper or operator will NOT function.
Designates communication between master and slave
operators only. M/S operators can be set for the same
or opposite phase, depending on operators
communication (can vary). See page 17.
Reset Button
Press for soft reset of operator (resets board microprocessor,
applies any changes that have been made to switches).
Turns OFF activated alarm. Try this button before preforming
a hard shutdown of operator (turn power switch OFF/ON)
when operator fails.
Multi Function
See page 15
AVI Slide Rev - C
Close Timer
Feature Selector
SELECT
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
OFF—ON
FEATURE SELECTOR
0
1
M/S PHASE
See page 14
ERD OVERLOAD
Not Used
Not Used
GND
#1
RCVR
Radio Receiver
24VAC
GND
See page 13
#2
Input/Output Connections
Descriptions - See page 15
Wiring Accessories - See page 16
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
FEATURE SELECTOR
-
See page 14
Reverse ERD
Sensor
See page 14
MASTER
OPEN RIGHT
OPEN
BRAKE ON
CLOSE TIMER ON
LIMIT
OPENING
CLOSING
TIMER
ERD CONTROL
S1 S2
FCN
ON ON
STOP N/C
ON OFF CLOSE
RESET
OFF ON
PHANTOM
OFF OFF EDGE SENSOR
MULTI FUNCTION
#3
#4
#5
#6
#7
#8
SLAVE MASTER
+ –
INPUT/OUTPUT
COMM PORT
COMM PORT
Master/Slave
See page 17
SELECT
SLAVE
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
OFF—ON
Limit Switches
See page 12
OPENING CLOSING CLOSED
LIMIT
GATE STATUS
Factory Set
ERD Sensor
"Fine Tune"
Adjustment.
Please call
Eagle
Access
before any
adjustment.
See page 14
Fuse
15 Amp
250V
Slow-Blow
#9
+ –
POWER
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents