Diamond Board Troubleshooting - Eagle 100 Series Installation & Owner's Manual

Swing gate operators diamond control board or diamond dc control board
Hide thumbs Also See for 100 Series:
Table of Contents

Advertisement

Diamond Board Troubleshooting

SYMPTOMS
(A) Gate operator is not plumb and level.
Gate stops and
reverses direction
(B) ERD current sensor may be set too sensitive.
in mid cycle and
the OVERLOAD
LED remains ON.
(C) Gate encountered an obstruction while cycling.
(A) The radio receiver's LED remains on.
(B) One or more of the global input LEDs remain active.
Gate will not close.
(C) Gate has re-opened because in encountered an
obstruction while closing.
(D) The loop detector LED is on.
(E) Switch #8 CLOSE TIMER is not functioning.
(A) Motor Overload LED is on.
(B) Radio receiver is not "ON" when the remote
control button is activated.
Gate will not open.
(C) The green "Power" LED is off.
(D) The Fuse is blown.
• Feature selector Switch #1 MUST be set to the "MASTER ON" position unless the operator is being used as a slave operator.
• Safety external loop detector must be connected to the "REVERSE LOOP" input (see pages 13 & 14).
• If the CLOSE TIMER feature is desired, switch #8 MUST be in the "ON" position.
• It is OK to call the Eagle Access Customer Service Department with any questions... we are here to serve YOU!
16
Diamond Board ONLY
PROBABLE CAUSE
COMMON OVERSIGHTS TO BE AWARE OF:
1-800-708-8848
REMEDY
(A) Remount operator.
(B) Turn the ERD current sensor slightly in the
clockwise direction.
(C) Check and remove all obstructions
(A) The radio receiver or remote control has
malfunctioned in the "ON" position.
(B) Check global inputs for a short circuit.
(C) Only Key/Keypad will resume normal operation.
(D) Reset loop detector. Verify correct loop wiring. Set
loop detector to a different frequency and/or change the
sensitivity of the loop detector.
(E) Be sure Switch #8 is in the "ON" position.
(A) Reset motor (see page 11).
(B) Radio receiver has malfunctioned in the "OFF"
position.
(C) Turn on operator power switch and/or reset the main
circuit breaker.
(D) Check and/or replace the fuse with same amp fuse.