Diamond Board Master / Slave Setup - Eagle 100 Series Installation & Owner's Manual

Swing gate operators diamond control board or diamond dc control board
Hide thumbs Also See for 100 Series:
Table of Contents

Advertisement

Diamond Board Master / Slave Setup

MASTER
BY EAGLE ACCESS CONTROL SYSTEMS, INC.
Operator
IMPORTANT:
The 115 VAC power for the master and slave operators MUST be on the same circuit breaker.
It is recommended that each gate operator's initial set-up is completed (Direction of gate travel, limit
switches, ERD reverse sensor and feature selector switches #1 - #4) before connecting the operators
together. After each operator functions individually, proceed to Master/Slave connection and operation.
#13
#14
SLAVE
MASTER
Diamond
+ –
+ –
Board
ONLY
(Master Operator)
COMM PORT
Feature Selector
(Master Operator)
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
REVERSE LOOP NO
REVERSE LOOP NC
OPN DLY S
ONE PASS
OPN DLY M
STOP-REVERSE
OPN DLY S
ALM-RST
OPN DLY M
CLOSE TIMER
OFF—ON
Use the feature selector to choose #2 - #8
options for the master operator. Switch #1
MUST be ON. Refer to page 9 for more
information about each of the features.
Close Timer
(Master Operator)
TIMER
Use the Close Timer (#8 ON) on the
master board only to set the gates
closing time 1 - 60 seconds.
Close Timer on the
slave operator
1 - 6 seconds
Diamond Board ONLY
Opens to the Left
Connect Master and Slave Operators Together
Choose your board type and use 20 GA stranded wire.
Correct polarity is VERY important. DO NOT cross
polarity. Operators will NOT function properly if not
wired correctly.
NOTE: #1 & #2 switch settings are
based on the illustration above.
ACCESSORIES NOTE: The Diamond Board
allow you to connect accessories to the master
or slave boards).
See page 14 for accessory wiring connections.
If NO gate delay is needed:
Switches #5 - #8 MUST be OFF.
Setting the OPEN Delay Feature:
#5 OPEN DELAY S: Turning #5 - ON delays opening the SLAVE gate by 1.5 seconds.
# 6 must be turned OFF. This is useful for magnetic lock applications.
#6 OPEN DELAY M: Turning #6 - ON delays opening the MASTER gate by 1.5 seconds.
# 5 must be turned OFF. This is useful for magnetic lock applications.
Setting the CLOSE Delay Feature:
#7 CLOSE DELAY S: Turning #7 - ON delays closing the SLAVE gate by 1 - 6 seconds,
adjustable by the close timer on the slave board. #8 must be turned OFF.
#8 CLOSE DELAY M: Turning #8 - ON delays closing the MASTER gate by 1 - 6 seconds,
TIMER
adjustable by the close timer on the slave board. #7 must be turned OFF.
Opens to the Right
Use the feature selector to choose #2 - #3
options for the slave operator. Switch #1
MUST be OFF. Switch #4 is not used.
Refer to page 9 for more information
about each of the features.
Gate Delay Functions
For overlapping bi-parting gates
Feature Selector
Switch #1 MUST be OFF (Slave Operator)
SLAVE
BY EAGLE ACCESS CONTROL SYSTEMS, INC.
Operator
#13
#14
SLAVE
MASTER
Diamond
+ –
+ –
Board
ONLY
(Slave Operator)
COMM PORT
Feature Selector
(Slave Operator)
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
REVERSE LOOP NO
REVERSE LOOP NC
OPN DLY S
ONE PASS
OPN DLY M
STOP-REVERSE
OPN DLY S
ALM-RST
OPN DLY M
CLOSE TIMER
OFF—ON
(Slave #5 - #8)
SELECT
SLAVE
MASTER
OPEN LEFT
OPEN RIGHT
BRAKE OFF
BRAKE ON
REVERSE LOOP NO
REVERSE LOOP NC
OPN DLY S
ONE PASS
OPN DLY M
STOP-REVERSE
OPN DLY S
ALM-RST
OPN DLY M
CLOSE TIMER
OFF—ON
15