Safety and Installation Guidelines 
Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are met when 
installing Waterlogic Equipment.   Only qualified service technicians should attempt installation and 
service of Waterlogic Equipment.     
 
WARNING!  ELECTRICAL SHOCK HAZARD.  Always unplug (isolate from power supply) to prevent 
electrical shock except where electrical tests are specified.   
 
       WARNING!  IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK. 
Connect to a 15 amp 120V 60Hz properly grounded outlet (GFI is recommended).  Ensure polarity is 
correct and always use a 3‐prong outlet.  Consult a qualified electrician if you have any questions.     
 
WARNING!  USE ONLY Waterlogic SUPPLIED POWER CORD (EL‐5001‐A).  Locate system within 5 
feet of power supply.  Never use an extension cord or adapter.  Do not use a damaged power cord or 
plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do not, under any 
circumstances, remove ground prong or alter the power cord.  Never pull the power plug from the 
outlet with a wet hand or allow the plug to get wet.  Failure to use the supplied power cord will void 
UL Certification and Warranty.   
 
CAUTION!  INDOOR USE ONLY.   Never exposed to direct sunlight, heat sources, or ambient air 
temperature above 97°F (3°6C) or below 50°F (10°C).  Install indoors and keep unit away from 
excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate clearance 
around the unit to allow refrigeration system condenser to dissipate heat.  Warmer environments 
require more clearance around the unit.  Minimum clearance around all surfaces of the machine is 2‐
inches.  Installs where the ambient temperature exceeds 80°F require a minimum of 4‐inches 
clearance for proper heat dissipation and efficient operation.    
 
CAUTION!  USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or 
damage caused by excessive water pressure.  Operating pressure must be 40 psi to 60 psi.  Be aware 
any of potential pressure surges caused by building/municipal pumping stations.   
 
CAUTION!  USE UV STABILIZED SUPPLY LINES.  Feed the unit with a potable ambient or cold‐water 
supply only.  Feed water over 105° F (40° C) can damage the treatment components.  Water block 
devices and external leak detectors are strongly recommended. Locate the unit as close to the water 
supply and the electrical connections as possible.   
 
       WARNING!  STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE USE. 
The unit must be completely drained and sealed before storing to avoid stagnation and reduce 
microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any 
potential microbiological contaminates
 
Pre‐installation and sanitization procedures as prescribed in this manual must be performed before 
installing the CUBE Water Treatment System. 
 
 
CUBE Manual 
 
INSTALLATION PROCEDURES 
 
                                                                        Page 56 – Revision 10‐8‐2018 