Commissioning, Inspec-Steps - Commissioning, Inspection And Maintenance - Viessmann Vitovalor PT2 Installation And Service Instructions For Contractors

Fuel cell based micro chp unit with integral gas condensing boiler and adjacent cylinder module natural gas version
Table of Contents

Advertisement

Steps - commissioning, inspection and maintenance
Commissioning steps
Inspection steps
Maintenance steps
1. Removing the front panels................................................................................................ 57
3. Filling the trap on the gas condensing module with water............................................ 58
4. Filling the fuel cell module trap........................................................................................ 59
5. Overview of water circuits................................................................................................. 60
6. Filling the DHW cylinder.................................................................................................... 61
7. Measuring static pressure................................................................................................. 62
8. Filling gas condensing module and heating circuits...................................................... 62
9. Commissioning the system............................................................................................... 65
10. Filling system separation circuit fuel cell module.......................................................... 68
11. Checking all connections on the heating water and DHW sides for leaks
12. Setting max. heating output (gas condensing module)................................................. 69
13. Naming the heating circuits.............................................................................................. 69
14. Entering heating contractor contact details.................................................................... 69
15. Measuring connection pressure (flow pressure) ........................................................... 69
17. Fuel cell module commissioning...................................................................................... 72
18. Starting maintenance mode.............................................................................................. 72
19. Converting the gas type on the fuel cell module............................................................ 73
21. Filling with distilled water and starting the system........................................................ 74
23. Tightness test on balanced flue system (annular gap check)....................................... 76
24. Burner removal (gas condensing module)...................................................................... 77
26. Checking the back draught safety device........................................................................ 79
28. Cleaning heating surfaces (gas condensing module).................................................... 80
30. Fitting the burner (gas condensing module)................................................................... 82
32. 5-yearly maintenance of fuel cell module........................................................................ 82
33. 10-yearly maintenance of fuel cell module...................................................................... 84
circuit................................................................................................................................... 85
pressure.............................................................................................................................. 85
Commissioning, inspection, maintenance
Page
55