Commissioning, Inspec-Steps - Commissioning, Inspection And Maintenance - Viessmann VITOCROSSAL CRU 800 kW Service Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

Steps - commissioning, inspection and maintenance
Commissioning steps
Inspection steps
Maintenance steps
1. Filling the heating system with water and venting.........................................................
2. Filling the trap with water..................................................................................................
3. Commissioning the system...............................................................................................
4. Checking the flue gas damper.......................................................................................... 10
5. Checking the gas type....................................................................................................... 10
6. Opening the boiler.............................................................................................................. 11
7. Conversion to natural gas E.............................................................................................. 12
8. Conversion to LPG P......................................................................................................... 13
9. Reducing the heating output (if required)........................................................................ 14
10. Checking the static pressure and supply pressure........................................................ 15
12. Checking the CO content.................................................................................................. 19
13. Checking the flue gas temperature.................................................................................. 19
14. Displaying the ionisation current..................................................................................... 19
15. Shutting down the system................................................................................................. 19
16. Opening the combustion chamber................................................................................... 19
17. Cleaning the combustion chamber and heating surfaces............................................. 20
18. Checking the gaskets and thermal insulation sections................................................. 20
tightness............................................................................................................................. 21
20. Cleaning the condensate drain pipe and trap................................................................. 21
22. Opening the burner door................................................................................................... 23
23. Checking the burner gauze assembly.............................................................................. 24
24. Checking the ignition electrodes and ionisation electrode........................................... 24
25. Cleaning the burner........................................................................................................... 25
26. Fitting the burner................................................................................................................ 26
27. Closing the burner door.................................................................................................... 26
28. Checking the gas train valves for tightness.................................................................... 28
29. Checking the gas train filter element............................................................................... 28
30. Checking the filter element in the gas line...................................................................... 29
31. Checking gas connections for tightness......................................................................... 29
32. Closing the boiler casing................................................................................................... 30
33. Checking the gaskets on the flue gas side...................................................................... 30
34. Performing final checks..................................................................................................... 30
35. Checking the water quality................................................................................................ 30
37. Checking the expansion vessel ....................................................................................... 30
38. Checking the mixer for ease of operation and leaks...................................................... 31
content................................................................................................. 16
2
Commissioning, inspection, maintenance
Page