Download Print this page

Dakota Digital BIM-01-2-EDBK Quick Start Manual page 3

Bus interface module for edelbrock engine management

Advertisement

Troubleshooting quick tips:
While the BIM is operating, the dot in the upper left corner of the display will indicate the status. On steady indicates it is
powered up but not receiving any BIM bus activity. Flashing indicates it is communicating on the BIM bus.
If the display shows "" then it is scanning to try and communicate with the Edelbrock system bus but cannot get an answer.
To see the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through several
screens. The first will show the bus type ("" Edelbrock). The next screens will indicate which (if any) extended data is
available: "" for intake/manifold temp.
To set or change the ID number:
The ID will not normally need to be changed. The fuel PSI and A/F ratio readings both use bus ID's so if you have other BIM
units connected along with this one there is a chance of ID conflicts. This can easily be resolved. If fuel PSI or A/F ratio is not
showing up in the BIM setup menu on your system you may need to resolve an ID conflict. The following procedure will allow the
BIM-01-2 to automatically select a new, unused ID.
Hold the switch on BIM while turning the key on. The BIM will show the current software code.
Release the switch.
Press and release the switch until "" is shown on the display.
Press and hold. "" will be shown while the BIM is scanning the bus for other BIM units.
When you see "" shown on the display release the switch.
The BIM unit will now go back to normal operation.
***Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the group screens if activated through the displays>>group set menu
setup.
Troubleshooting guide
Problem
o
BIM will not light up at all
BIM display is scanning ""
o
o
BIM has a steady dot lit
BIM display shows ":"
o
DAKOTA DIGITAL offers complete service and repair of its product line. In addition, technical
consultation is available to help you work through any questions or problems you may be having installing one
of our products. Please read through the Troubleshooting Guide. There, you will find the solution to most
problems.
Should you ever need to send the unit back for repairs, please call our technical support line, (605) 332-
6513, to request a Return Merchandise Authorization number. Package the product in a good quality box
along with plenty of packing material. Ship the product by UPS or insured Parcel Post. Be sure to include the
RMA number on the package, and include a complete description of the problem with RMA number, your full
name and address (street address preferred), and a telephone number where you can be reached during the
day. Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase.
Send no money. We will bill you after repair.
Possible cause
• PWR wire does not have power.
• Power/data harness is damaged.
• Module is damaged.
• Adapter harness is not connected
• The Edelbrock system is not compatible
• The Edelbrock is not powered on.
• Edelbrock system has old firmware
Interface cable is not connected
Interface cable is loose.
On VHX systems, the BIM display for this is disabled.
Data cable is damaged.
Another module on the bus is damaged or connected
improperly.
SERVICE AND REPAIR
Solution
• Connect to a location that has +12V key-on power.
• Inspect harness and repair or replace.
• Return for service. (See Instructions below)
• Connect to a different ground location
• Connect the appropriate harness to Edlebrock CAN
• Verify compatibility.
• Verify Edelbrock system is powered on.
• Update firmware to v53 or later
• Connect the supplied data cable between the BIM
unit and the gauge control box.
• Make sure both ends of the cable are seated.
• Follow instructions in VHX manual to enable the
BIM display screen.
• Inspect and replace the data cable.
• Inspect other modules on the bus.
MAN #650687D

Advertisement

loading