The ALARM LED indicates the presence, or absence, of an unread system
alarm(s). Unread system alarms can be read using the LCD and five-function
keypad. The possible states and descriptions of the ALARM LED are listed in
Table 3-5.
Green
Yellow
Red

Out-of-Band Management

Out-of-band management refers to managing the system via a Local Management
(LM) connection or an SNMP-based management application that does not use
the same network connection to the chassis as "user data."
The 9C300-1 Environmental Module provides four out-of-band management
interfaces for managing the SmartSwitch 9000 system. These interfaces are listed
below:
• Two serial communication ports, COM1 and COM2
• One standard Cabletron EPIM interface
• Liquid Crystal Display (4 lines by 40 characters) and an associated five button
keypad

COM1 and COM2 Ports

The 9C300-1 Environmental Module front panel has two RJ-45 communication
ports for RS-232 serial communication to and from the SmartSwitch 9000.
Figure 3-5 illustrates a single RJ-45 communication port connector. COM1 and
COM2 can be configured to run the Serial Line Internet Protocol (SLIP), Point-to-
Point Protocol (PPP), Local Management via a terminal or modem connection, or
monitor an American Power Conversion Smart UPS. Refer to the Local
Management Manual for detailed information on configuring the COM1 or
COM2 port.
LED Color
State
Functional
Functional
Functional
9C300-1 Environmental Module Operation
Table 3-5. ALARM LED
No unread alarms.
Pending unread system alarms, warning.
Pending unread system alarms, critical.
Description
3-7