707
Event Log Message
Host Console Message
Alert Condition
Alert ID Number
Alert Type
Alert Descr iption
Probable Causes
User Causes
Install Causes
Failure Causes
Actions
Additional SVs
18
puname/linename – SDLC Stn rcvd FRMR - Ifld too long
SOFTWARE PROGRAM ERROR:SDLC COMMUNICATIONS
An SDLC logical link has been lost. The primary link station sent a fr ame with an i-field
that was too long. The secondary link station responded with a Frame reject.
X'BA35EC4D'
X'01'
Permanent
X'2100'
Softwar e Program Error
X'2004'
SDLC communications
X'1000'
Softwar e program
(none)
(none)
X'1000'
Softwar e program
X'F013'
Frame reject received: Maximum I-field length exceeded
(Sender-specific actions)
X'52'SV
LCS Configuration
X'02'SF
Rem ote Device Address
X'04'SF
Local Device Address
X'06'SF
Link Station Attributes
X'07'SF
Link Attributes
X'8C'SV
Link Station Data
X'01'SF
Current Ns/Nr Counts
X'02'SF
Outstanding Fr ame Count
X'03'SF
Last Control Field Received
X'04'SF
Last Control Field Sent
X'05'SF
Sequence Number Modulus
X'06'SF
Link Station State
X'07'SF
LLC Reply Timer Expiration Count
X'08'SF
Last Received Nr Count
X'05'SV
Hierarchy/Resource List
X'10'SF
Hierarchy Name List
First resource below sender :
Second resource below sender:
Resource Name = (LINE NAME)
Resource Type = X'3D'(LINE)
Resource Name = (Physical Unit Name)
Resource Type = X'80'(Physical Unit)
NetView Service Point
Need help?