York YAFS018 Installation Manual page 47

Hide thumbs Also See for YAFS018:
Table of Contents

Advertisement

Wiring Schematics cont.
Aurora Advanced with 5-Speed ECM cont.
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
CC2
G
LO
HI
CCG
CC
FG
F
R
F
CC
G
Y1
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
FP1 – 15
F/30
o
ECM PWM
P4
R
FP2 – 15
F/30
o
P13
RV – B/O
Fault
ACC – Dip 4
ACC – Dip 5
CC – Dual/Single
SW1 Test
G
L – Pulse/Continuous
Status
Reheat/Normal
RV – K1
AURORA BASE
CC – K2
CONTROL™
P5
CC Hi – K3
Fan – K4
P11
Alarm – K5
JW2 - Alarm
Acc – K6
P9
Factory Fan Connection
Field Connections
Field Connections
P2
P1
AXB Accessory 2 DIP Se ngs
SW1-4
SW1-5 DESCRIPTION
ON
ON
Cycles with Blower
OFF
ON
Cycles with CC rst stage compressor or compressor spd 1-12
ON
OFF
Cycles with CC2 second stage of compressor or comp spd 7-12
OFF
OFF
Cycles with DH from ABC board
DESCRIPTION
Cycle with Blower
Cycle with Compressor
Water Valve Slow Opening
Cycle with Comm. T-stat Hum Cmd
Off
On
F
o
1
EH1
2
F
Y
o
3
Config
EH2
P3
4
C
5
EH1
C
6
CO
7
N/A
8
SW2
(+)
P6
(-)
R
C
(+)
P7
(-)
G
Com1
R
C
P8
G
Com2
R
R
ABC SW2 Accessory Relay
SW2-4
SW2-5
ON
ON
OFF
OFF
ON
OFF
OFF
ON
47
Communicating Thermostat
Dual Fuel Wiring Diagram
Using Field Installed Relay
Note 11: Field installed SPST dual fuel relay
(Required for dual fuel installation)
EH1
ABC
Board
C
Thermostat
Traditional Thermostat
Y1
1st Stage Compressor
Dual Fuel Wiring Diagram
Using Field Installed Relay
Y2
2nd Stage Compressor
O
Reversing Valve
Fossil Fuel
L
Fault Signal
Furnace
C
C
Common
Common
R
R
24 VAC
24 VAC
W
Auxiliary Heat Relay
G
G
Fan
Auxiliary
Heat Relay
W
Auxiliary Heat Relay
Note 11: Field installed SPST dual fuel relay
(Required for dual fuel installation)
Figure 1:
K6 Relay
Optional Internal
Hot Water
Generation Pump
COM
Wiring Schematic
Blue
DHW
Cabinet
Pump
HW
Switch
Blue
3
1
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will be connected to the auxiliary
heat unit. The auxiliary heat unit will then power the blower. Refer to EAS/EAM/EAL
Auxiliary Heat kit installation instructions. Wires are secured at blower
4 – Low voltage wiring CLASS 2.
5 - Y2 input wire Tan not connected on Single Speed units. Wire is secured at blower.
6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 – Brown blower power wire routed through Current Transducer two times.
8 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
9 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
10 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
11 - Field installed SPST relay required for dual fuel installation.
12 - Refer to units 5 SPEED ECM MOTOR LOW VOLTAGE CONNECTION table for
factory settings.
MODULATING VALVE
AXB BOARD
1
2
GND
1
24 VAC
2
C
0-10DC
3
R
ABC BOARD
To Fossil Fuel
R from Fossil
Furnace W input
Fuel Furnace
24VDC
ABC Board
Y1
Y2
O
P1
LO
C
R
P2
ES
= chassis
Connects to L2
and NO on
AXB Board
NO
L2
Purple
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yafs012Yaft026Yaft072Yzfs018Yzft026Yzft072

Table of Contents