York YAFS018 Installation Manual page 27

Hide thumbs Also See for YAFS018:
Table of Contents

Advertisement

Horizontal Dimensional Data
Primary Service Access
FRONT VIEW
A
S
1.9in
[4.8cm]
K J I
Overall Cabinet
Horizontal
Model
A
B
C
Width Depth Height
in.
22.5
44.0
17.3
012
cm.
57.2
111.8
43.9
in.
22.5
53.0
19.3
018
cm.
57.2 134.6 49.0
in.
22.5
63.0
19.3
022-
030
cm.
57.2 160.0 49.0
in.
25.6
72.0
21.3
036-
038
cm.
65.0 182.9 54.1
in.
25.6
77.0
21.3
042-
049
cm.
65.0 195.6 54.1
in.
25.6
82.0
21.3
060-
072
cm.
65.0 208.3 54.1
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front
Unit shipped with deluxe 2 in. (field adjustable to 1 in.) duct collar/filter rack extending from unit 3.25 in. and is suitable for duct connection.
Discharge flange is field installed and extends 1 in. [25.4mm] from cabinet
Decorative molding and/or water connections extend 1.2 in. [30.5mm] beyond front of cabinet.
Units Not Shown Above
Right Return End Discharge
Right Return Side Discharge
Left Return End Discharge
Left Return Side Discharge
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
2ft [61cm]
D E F
G
AS SHOWN LR UNIT (RR UNIT ON OPPOSITE SIDE—SAME DIMENSIONS)
Water Connections
D
E
F
G
H
HWG
HWG
Cond-
In
Out
In
Out
ensate
2.3
5.3
11.9
14.9
8.0
5.8
13.5
30.2
37.8
20.3
2.3
5.3
13.8
16.8
8.0
5.8
13.5
35.1
42.7
20.3
2.0
7.0
13.5
16.5
0.8
5.1
17.8
34.3
41.9
2.0
2.3
7.3
15.9
18.9
0.8
5.8
18.5
40.4
48.0
2.0
2.3
7.3
15.9
18.9
0.8
5.8
18.5
40.4
48.0
2.0
2.3
7.3
15.9
18.9
0.8
5.8
18.5
40.4
48.0
2.0
L
in
2.8
cm
7.1
in
4.9
cm
12.4
in
4.9
cm
12.4
in
2.8
cm
7.1
TOP VIEW
SIDE DISHCARGE VIEW
B
Electrical
Connections
I
J
3/4 in.
1/2 in.
1/2 in.
Loop
HWG
cond
cond
cond
Water
Sweat
Power
Ext
Low
FPT
(I.D.)
Supply
Pump
Voltage
6.9
9.5
11.7
1 in.
1/2 in.
Swivel
Female
17.5
24.1
29.7
6.9
9.5
11.7
1 in.
1/2 in.
Swivel
Female
17.5
24.1
29.7
9.5
12.1
14.3
1 in.
1/2 in.
Swivel
Female
24.1
30.7
36.3
9.5
12.1
14.3
1 in.
1/2 in.
Swivel
Female
24.1
30.7
36.3
9.5
12.1
14.3
1 in.
1/2 in.
Swivel
Female
24.1
30.7
36.3
9.5
12.1
14.3
1 in.
1/2 in.
Swivel
Female
24.1
30.7
36.3
O
4.6
11.8
6.9
17.5
7.6
19.4
6.9
17.5
27
P
Q
2.1in [5.4cm]
MOUNT (2) HANGER BRACKETS
AS SHOWN TO ALLOW ACCESS
TO FILTER
L
L
N
O
M
C
H
Discharge Connection
duct flange installed (±0.10
K
in)
L
M
N
O
Supply
Supply
Height
Depth
4.1
7.3
9.7
5.8
10.4
18.5
24.6
14.7
1.8
10.5
9.5
8.2
4.6
26.7
24.1
20.8
2.3
10.5
9.4
5.8
5.8
26.7
23.9
14.7
13.6
13.2
SEE
SEE
CHART
CHART
34.5
33.5
13.6
13.2
SEE
SEE
CHART
34.5
33.5
CHART
13.6
13.2
SEE
SEE
CHART
CHART
34.5
33.5
END VIEW
S
O
R
Return Connection
using std deluxe filter rack
(±0.10 in)
P
Q
R
S
Return
Return
Depth
Height
1.7
17.8
14.6
1.4
4.3
45.2
37.1
3.6
2.2
21.8
16.5
1.5
5.6
55.4
41.9
3.8
2.8
30.5
16.9
1.3
7.1
77.5
42.9
3.3
2.8
35.5
18.9
1.3
7.1
90.2
48.0
3.3
2.8
40.4
18.9
1.3
7.1
102.6 48.0
3.3
2.8
45.4
18.9
1.3
7.1
115.3
48.0
3.3
7/11/12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yafs012Yaft026Yaft072Yzfs018Yzft026Yzft072

Table of Contents