Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart cont.
NOTE 3
Brown
Orange
Green
1
2
3
4
5
P11
ECM
Blower
Motor
12 15 10
16 1
3 3
P12
Violet(42)
Blue(24)
Yellow(25)
Green/Yellow(28)
NOTE 9
To P2 on
Electric Heat
Board
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
NOTE 4
Brown
To PB2
Orange
Blue
Green
1
2
3
4
Connects to variable
speed ECM motor only
CSA installed units only
Local codes may require a single
source of power supply
Single Disconnect Power
208-230/60/1
Breaker box
L1
L2
furnished by
installer
Circuit Breakers
L1
L2
L1
Aux Elect Power
Unit Power
208-230/60/1
208-230/60/1
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
4 – Low voltage wiring CLASS 2.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
7 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
8 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
9 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
10 – Ground wire only on units with aluminum air coils.
With optional EA Series 20kW Auxiliary Electric Heat shown
Place auxiliary heat schematic from kit here
208-230/60/1
208-230/60/1
Circuit 2
Circuit 1
NOTE 2
G
L2
L1
L2
L1
P9
1
Green
2
3
Brown
5
Orange
4
Violet
Gray
5
P11
Yellow
Pink
C
1
P3 from unit's control box
connects to P2
L2
L1
CC -
Compressor Contactor
CO -
Condensate overflow sensor
K5 -
DHW pump relay
Loop pump relay
K6 -
PSC Fan Speed Relay
CR3 -
CR4 -
PSC Fan Power Relay
CS -
Compressor Solenoid
F1 and F2 -
Fuses
HE -
Heater element
HP -
High pressure switch
ER1 to ER4 -
Aux heat stage relays
LP -
Low pressure switch
41
1 - Use copper or aluminum conductors.
2 - Use manufacturer's part number 19P592-01 (jumper
bar assembly) when single source power is required.
3 – When Auxiliary Heat is installed the BLK/WHT
G
wire from CC-L1 to PB2-2 and the GRY/WHT wire
from CC-L2 to PB2-1 must be removed (located in
the heat pump control box).
4 - When installed, the Auxiliary Heat powers blower and controls.
5 – Low voltage wiring CLASS 2.
6 – Jumpers wires are Factory Installed, and are
required for auxiliary heat operation.
Black
Gray
EHC
Pink
Yellow
ER1
Gray
G
NO
Blue
HE1
EHC
ER2
Black
Black
G
NO
HE2
Blue
ER3
Yellow
HE3
G
NO
ER4
Pink
G
NO
HE4
EA Series PCB
P2
P1
2
3
4
C
1
2
3
4
NOTE 6
Legend
Factory Low voltage wiring
Thermistor
T
Factory Line voltage wiring
Field low voltage wiring
Light emitting diode - Green
G
Field line voltage wiring
Optional block
Relay coil
DC Voltage PCB traces
Junction
Capacitor w/ bleed resistor
Quick connect terminal
Switch - Condensate overflow
Wire nut
Switch - High pressure
Field wire lug
Switch - Low pressure
Ground
Relay Contacts-
2
3
1
Polarized connector
N.O., N.C.
P
Fuse
Current Transducer (CT)
Breaker
PB1, PB2 -
Power blocks
PS -
Power strip
RV -
Reversing Valve coil
SW1 -
DIP package 5 position AXB
SW1 -
TEST MODE ABC Board
SW2 -
DIP package 8 position ABC Board
TS -
Thermal limit switch
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
WCL -
Water Coil Limit Sensor
Gray
TS1
Black
TS2
Yellow
TS3
Pink
TS4