Wiring Schematics cont.
Aurora Advanced with ECM and IntelliStart cont.
HP
P4
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
CC2
G
P5
LO
HI
CCG
CC
FG
F
R
JW2 - Alarm
F
CC
G
Y1
P2
AFFINITY & AFFINITY ADVANCED SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
Off
FP1 – 15
F/30
F
o
o
ECM PWM
R
F/30
F
FP2 – 15
o
o
P13
RV – B/O
Fault
ACC – Dip 4
ACC – Dip 5
CC – Dual/Single
SW1 Test
G
L – Pulse/Continuous
Status
Reheat/Normal
RV – K1
AURORA BASE
CC – K2
CONTROL™
CC Hi – K3
Fan – K4
P11
Alarm – K5
Acc – K6
P9
Factory Fan Connection
Field Connections
Field Connections
P1
Legend
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Junction
Quick connect terminal
Wire nut
Field wire lug
L1
Ground
Relay Contacts-
2
N.O., N.C.
P
Fuse
Breaker
CC -
Compressor Contactor
CO -
Condensate overflow sensor
K5 -
DHW pump relay
Loop pump relay
K6 -
CR3 -
PSC Fan Speed Relay
PSC Fan Power Relay
CR4 -
CS -
Compressor Solenoid
F1 and F2 -
Fuses
HE -
Heater element
HP -
High pressure switch
ER1 to ER4 -
Aux heat stage relays
LP -
Low pressure switch
On
1
EH1
2
Y
3
Config
P3
EH2
4
C
5
EH1
C
6
CO
7
N/A
8
SW2
(+)
P6
(-)
R
C
(+)
P7
(-)
G
Com1
R
C
P8
G
Com2
R
R
Thermistor
T
Light emitting diode - Green
G
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Low pressure
3
1
Polarized connector
Current Transducer (CT)
PB1, PB2 -
Power blocks
PS -
Power strip
RV -
Reversing Valve coil
SW1 -
DIP package 5 position AXB
SW1 -
TEST MODE ABC Board
SW2 -
DIP package 8 position ABC Board
TS -
Thermal limit switch
HWL -
Hot water limit sensor
SC -
Start Contactor
Start Relay
SR -
WCL -
Water Coil Limit Sensor
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will then be connected to
the auxiliary heat unit. The auxiliary heat unit will then power the blower. Refer to
EAS/EAM/EAL Auxiliary Heat kit installation instructions.
4 – Low voltage wiring CLASS 2.
5 – Brown blower power wire routed through Current Transducer two times.
6 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
7 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
8 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
9 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
43
MODULATING VALVE
GND
1
24 VAC
2
0-10DC
3
Communicating Thermostat
To Fossil Fuel
Furnace W input
Dual Fuel Wiring Diagram
Using Field Installed Relay
Note 11: Field installed SPST dual fuel relay
(Required for dual fuel installation)
EH1
ABC
Board
C
Thermostat
Traditional Thermostat
Y1
1st Stage Compressor
Dual Fuel Wiring Diagram
Using Field Installed Relay
Y2
2nd Stage Compressor
O
Reversing Valve
Fossil Fuel
L
Fault Signal
Furnace
C
C
Common
Common
R
R
24 VAC
24 VAC
W
Auxiliary Heat Relay
G
G
Fan
Auxiliary
Heat Relay
W
Auxiliary Heat Relay
Note 11: Field installed SPST dual fuel relay
(Required for dual fuel installation)
Figure 1:
K6 Relay
Optional Internal
Hot Water
Generation Pump
COM
NO
Wiring Schematic
Blue
DHW
Cabinet
Pump
HW
Switch
Blue
3
2
1
Notes
AXB BOARD
1
2
C
R
ABC BOARD
R from Fossil
Fuel Furnace
24VDC
ABC Board
Y1
Y2
O
P1
LO
C
R
P2
ES
= chassis
Connects to L2
and NO on
AXB Board
L2
Purple