York 036-048 Technical Manual

York 036-048 Technical Manual

Split-system heat pumps 10 seer – r-22

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM HEAT PUMPS
10 SEER – R-22
MODELS:
E*RA036 THRU 060
(3 THRU 5 NOMINAL TONS, 3 PH)
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
MODELS: 036-048 (3 PH)
MODELS: 060, 090 (3 PH)
ISO 9001
Certified Quality
Management System

DESCRIPTION

The 10 SEER Series heat pumps is the outdoor part of a ver-
satile system of heat pumps. It is designed to be custom-
matched with one of UPG's complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air han-
dlers.
WARRANTY
1-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

• QUALITY COILS - The coil is constructed of copper tube
and aluminum fins.
• COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, a single panel covering the electrical controls,
and the molex plug in the control box connecting the con-
denser fan make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment cer-
tification program, which is based on ARI Standard 210/240.
279104-YTG-B-0307

Advertisement

Table of Contents
loading

Summary of Contents for York 036-048

  • Page 1 Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ari.org/aridirectory. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2 279104-YTG-B-0307 Physical and Electrical Data MODEL E1RA036S25 Unit Supply Voltage Normal Voltage Range Minimum Circuit Ampacity Max. Qvercurrent Device Amps Compressor Type Compressor Amps Rated Load Locked Rotor Crankcase Heater Fan Motor Amps Rated Load Fan Diameter Inches Fan Motor Rated HP Nominal RPM Nominal CFM...
  • Page 3 Additional R-22 Charge / Orifice Size for Various Matched Systems Outdoor Unit E1RA036S(25,46) Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil FC/MC/PC35(B,C)3X FC/MC/PC/UC36(A,B,C)3X FC/MC/PC/UC42(B,C)3X FC/MC/PC/UC48C3X FC/MC/PC/UC48D3X FC/MC/PC/UC60C3X FC/MC/PC/UC60D3X AHP36C3X AHP42C3X AHP/SHP48D3X AHP60D3X G1NA036S17L G1NA048S21D G1NA048S24P G1UA048S21/24 G1UA060S24 G1FA048S21/24 G1FA060S24 G2FD042S21 G2FD048S21/24 G2FD060S24...
  • Page 4 279104-YTG-B-0307 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL MODEL MA12BN2,4 MA12BN2,4 E1RA036S(25,46) MA12BN2,4 N1AHC1646 MA16CN4 MA20DN2 E2RA048S(25,46 MA20DN4 N1AHC1646 N1AHD2046 MA20DN4 E1RA060S(25,46) N1AHD2046 F2RP/FP036 5, 8, 10, 15, 19 F2RD/FP042 E1RA036S25 AHP36C3X AHP42C3X F2FP048 5, 8, 10, 15, 20, 25 E2RA048S25 F2FP060 5, 8, 10, 15, 20, 25...
  • Page 5 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** UNIT MODEL CFM RANGE (MIN.-MAX.) 21,24 21,24 1100 E1RA036S(25,46 1400 17,21 14,17,21 17,21 21,24 21,24 1400 E2RA048S(25,46 1800 21,24 21,24 21,24 1600 E1RA060S(25,46) 2100 1. TXV = Use 1TV700 Series Kit. Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.
  • Page 6 279104-YTG-B-0307 HEATING PERFORMANCE - With Air Handler UNIT COIL MODEL* MODEL MBH COP MBH COP STD MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW F2RP/F2FP036 34.0 3.00 20.4 2.16 E1RA036S(25,4 AHP36,42 34.0 3.00 20.4 2.16 F2FP048 37.0 3.08 31.4 2.32 E2RA048S(25,46...
  • Page 7 ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA067*) Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied. Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit.
  • Page 8 279104-YTG-B-0307 TYPICAL FIELD WIRING - 3 PH (036 - 060) ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES THERMOSTAT B or C L or X FIELD INSTALLED JUMPER JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT.
  • Page 9 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 10 279104-YTG-B-0307 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 11 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. T.C. S.C. NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections.
  • Page 12 279104-YTG-B-0307 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR INDOOR UNIT COIL NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil MA12BN2,4...
  • Page 13 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR INDOOR UNIT COIL NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil MA16CN2,4...
  • Page 14 279104-YTG-B-0307 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EVAPORATOR COIL MODEL NO AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR INDOOR UNIT COIL NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. Air Handler Coil MA20DN2,4...
  • Page 15 279104-YTG-B-0307 NOTES Unitary Products Group...
  • Page 16 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2007. All rights reserved. Unitary Product Group NOTES 5005 York Drive 279104-YTG-B-0307 Supersedes: 279104-YTG-A-1106 Norman 73069...