Installation Environment Requirements
Item
Operating ambient temperature
Operating ambient humidity
Non-operating ambient
temperature
Non-operating ambient humidity 10 - 90%RH (No condensation)
Floating dust particles
Corrosive gases
Line-noise
Line noise
resistance
Static
electricity
resistance
Vibration
Sweep
resistance
resistance
Shock resistance
Grounding
Standard
*7 If you use the USB with bus power, operate the product at between -20 and +55°C.
*8 When you use the CPS-PWD15AW12-01 (optional product).
*9 When you use an optional power product: 10-55Hz (See the manual of optional power product
for details)
Appendix
CPS-MC341-ADSC1-111
CPS-MG341-ADSC1-111
-20 - +60°C *7
10 - 90%RH (No condensation)
-20 - +60°C
Not to be excessive
None
AC Line/±2kV *8
Signal Line /±1kV(IEC61000-4-4 Level 3, EN61000-4-4 Level 3)
Touch /±4kV(IEC61000-4-2 Level 2, EN61000-4-2 Level 2)
Air /±8kV(IEC61000-4-2 Level 3, EN61000-4-2 Level 3)
10 - 57Hz *9 /semi-amplitude vibration 0.15mm,
57 - 150Hz/2.0G
40minutes each in X, Y, and Z directions (JIS C60068-2-6-compliant,
IEC60068-2-6-compliant)
15G half-sine shock for 11ms in X, Y, and Z directions
(JIS C 60068-2-27 –compliant, IEC 60068-2-27 -compliant)
Class D grounding (previous class 3 grounding), SG-FG/ non-conduction
VCCI Class A, FCC Class A,
CE Marking (EMC Directive Class A, RoHS Directive), UL
— 75 —