480 HD INSTALLATION INSTRUCTIONS
Point out the position of the power source for the appliance, plus demonstrate using the
addition battery holder and adaptor lead, the battery backup option. ("C" cell batteries not
included within this appliance).
Demonstrate the lighting and extinguishing procedures to the user and the removal and refit
of the glass panel for cleaning and the fitting of the battery backup kit.
Hand these instruction over to the user along with the battery holder, adaptor lead plus M4
nut spinner for the removal of the glass panel.
Please be aware that the non-reflective glass may in some lights and from some angles have
a blue tinge to it this is perfectly normal. Also be aware that if the glass liners are fitted in the
fire with the non-reflective glass you will still have a reflection in the glass liners.
480 HD SERVICE / FAULT FINDING INSTRUCTIONS

Annual Service Requirement.

General
Servicing should be carried out annually by competent person whose name
appears on the gas safe register. All Gas Safe engineers should possess an ID
carrying the logo below.
Before commencing any service or replacement of part, turn off the gas supply to the fire.
After servicing check for gas soundness.
When ordering spare parts please quote the appliance name and serial number.
Check for debris
At least once a year check for debris in the catchment area behind the fire and in the flue
way. To undertake this check the following procedure should be followed.
Remove the two M4 nuts fixing the glass clamp to the glass panel. (See Fig 8). With the nuts
removed, pull the glass clamp clear of the four studs. Finally lift the glass panel out of the
bottom glass fixing.
Remove the log shapes.
Lift out the air tray assembly from within the fire box shelf.
LT 7602 Issue No2 (07/17)