The following tables assume that Installer Menu item 118 POWER SAVINGS is set to 3 (default)
and Installer Menu item 099 BACK LIGHTING is set as shown below (default value is 255).
Item 099
Back Lighting
(Static)
100
90
80
70
60
50
40
30
20
10
1
Item 099
Back Lighting
(Dynamic)
200
190
180
170
160
150
140
130
120
110
101
Note: Values are results of controlled experiments under laboratory conditions.
206-4271
32LY770M
Power
Percent
Consumption
Savings
(Watts)
50.4
0.0%
47.9
5.0%
46.0
8.7%
43.8
13.1%
41.4
17.9%
39.2
22.2%
37.2
26.2%
35.0
30.6%
33.1
34.3%
30.8
38.9%
28.9
42.7%
32LY770M
Power
Percent
Consumption
Savings
(Watts)
50.2
0.0%
47.9
4.6%
46.0
8.4%
43.8
12.7%
41.4
17.5%
39.2
21.9%
37.3
25.7%
35.0
30.3%
33.0
34.3%
30.8
38.6%
28.8
42.6%
Reference: Power Consumption Settings
42LY770M
Power
Consumption
(Watts)
64.4
60.8
57.8
54.3
50.6
47.1
44.1
40.6
37.5
33.9
30.7
42LY770M
Power
Consumption
(Watts)
65.0
61.3
58.2
54.6
50.9
47.4
44.3
40.8
37.7
34.0
30.8
Percent
Savings
0.0%
5.6%
10.2%
15.7%
21.4%
26.9%
31.5%
37.0%
41.8%
47.4%
52.3%
Percent
Savings
0.0%
5.7%
10.5%
16.0%
21.7%
27.1%
31.8%
37.2%
42.0%
47.7%
52.6%
77