Download Print this page

Kirby Morgan SuperFlow 525-757 Manual page 4

450 regulator parts upgrade kit

Advertisement

Kirby Morgan Dive Systems, Inc.
1430 Jason Way Santa Maria, California 93455
Phone: 805/928-7772
www.KirbyMorgan.com email: kmdsi@KirbyMorgan.com
NOTE: The wings that align with the
Lever Arm are the two that have an
additional wall for the Lever Arm to
bear on. The Inlet Valve Assembly
should be inserted into the Main Tube
with these walls toward the bottom of
the regulator tube.
2. Insert the Balance Spacer with the two O-rings installed. Insert the first O-ring into the open end of the
inlet valve stainless steel tube and stop at the second O-ring. Next, align and insert the Inlet Valve into
the Main Tube, as noted above. If this is done properly, the lever should lift up. If it does not, the Inlet
Valve has not been aligned correctly.
4. Install the Spring and Balance Spacer with O-ring into
the Main Tube. Make sure the Balance Spacer is properly
aligned inside the Main Tube by pushing in on the end of
the Balance Spacer and slightly turning it with your finger
tip to see that it moves inward (i.e., it engages the hole in
the Inlet Valve).
© MMXVII Kirby Morgan Dive Systems, Inc. All Rights Reserved
Fax: 805/928-0342
3. While holding the Inlet Valve in position, pinch each arm of
the Lever Arm and slowly remove the Balance Spacer and
O-rings. The Inlet Valve should remain in place. If it comes
out, repeat the process until the Inlet Valve stays in place.
NOTE:
BROWN indicates the current Balance Spacer.
DARK GREY indicates the earlier Balance Spacer.
Both are fit for use. Difference in color ONLY.
Document # 170525006
®
Page 4 of 8
"WINGS"
AREA THE LEVER
FITS INTO

Advertisement

loading