Download Print this page

Kirby Morgan SuperFlow 525-757 Manual page 5

450 regulator parts upgrade kit

Advertisement

5. Lightly lubricate the ends of the Transfer Pin and install into the end of the Balance Spacer. Thread the
Flex Knob Assembly onto the end of the Main Tube (closest to the lever arms) until it just stops. Hand
tighten the Flex Knob Assembly and then back the Flex Knob out three turns.
Installing the Main Tube Assembly into Regulator Body
1. Ensure O-ring on Main Tube is in good condition and lubricated with
Christo-Lube
or equivalent.
®
© MMXVII Kirby Morgan Dive Systems, Inc. All Rights Reserved
Kirby Morgan Dive Systems, Inc.
1430 Jason Way Santa Maria, California 93455
Phone: 805/928-7772
www.KirbyMorgan.com email: kmdsi@KirbyMorgan.com
6. Install the Bearing Clip onto the outside of the Main Tube. Note that
there is a locating pin on the clip that must engage the correct hole on
the Main Tube. There are also small recesses on either side that the
legs of the Lever Arm fit into. The clip is correctly positioned when it
is in the position shown.
NOTE: For ease of installation, the spring tension on the Lever Arm may
require the Lever Arm to be pulled more against the Spring to align the
Balance Spacer.
Fax: 805/928-0342
Page 5 of 8
Document # 170525006
®

Advertisement

loading