Bent Tube Removal
Installing the 455 Balanced Regulator
Part #
100-100
100-204
505-455
520-042
1.1 SuperFlow
350 Regulator
®
Removal
Tools Required:
• Socket Wrench
• 1 3/8" socket or Regulator Mount Socket Wrench
P/N 525-625 (Found in 525-620 Tool Kit).
• 3/8" Drive Extension—Minimum 3" in Length
• 1/ 4 " Flat Blade Screwdriver
• 7/16", 11/16" and (2) 7/8" Open End Wrenches
• Slip Joint Pliers and a Cloth
1.1.1 Bent Tube Removal
1. Always start removal at the side block end.
Loosen the tube with the 11/16 inch wrench. The
free swiveling mount nut on this end of the bent
tube can be un-threaded completely and can
slide down the tube.
Always start removal at the side block end.
18
onto a KMB 18/28 Band Mask
Parts Included in the 525-765 Kit:
Description
Warranty Card
Installation Guide, 455 Regulator Kit
455 Balanced Regulator
Tie Wrap
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210607001
SuperFlow® 350 Regulator Removal
Qty
1
1
1
2
2. Loosen the lower bent tube nut by using the
two 7/8 inch wrenches. Place one wrench on the
bent tube mount nut and the second on the
regulator inlet jam nut. Turn only the outer nut
on the bent tube to loosen the bent tube.
3. With the two mount nuts free; the bent tube
assembly can be pulled straight out and away
from the regulator. The bent tube assembly
can be rotated back and forth to aid removal, if
necessary.