Power Requirements - Shure DDS 5900 User Manual

Discussion system
Hide thumbs Also See for DDS 5900:
Table of Contents

Advertisement

Shure Incorporated
Wireless Language Distribution
Emergency Signal
Input 2 is designed to broadcast an Emergency Evacuation Message (EEM), overriding the discussion in the event of an emer-
gency. A switch (normally-open) must be connected to the emergency switch connector. When the switch is closed an "Emer-
gency Evacuation Message (EEM)" audio signal present on the 'In 2' input is distributed to all output channels, overriding all
other audio inputs.

Power Requirements

For most installations, the DIS-CCU supplies sufficient power for the discussion units. Depending on the setup, the CCU pow-
ers up to 50 units at a time without additional equipment. The number of supported discussion units depends on the size and
layout of the installation.
Note: maximum cable length in one chain is 120 m before a repeater unit.
25/81

Advertisement

Table of Contents
loading

Table of Contents